EN - ENGLISH (translated from the original manual)
MAIN FEATURES
•
Full Range AC Power Supply (100 – 230V).
•
Embedded 433.92MHz digital radio frequency receiver.
•
Encrypted and detachable EEPROM memory for storage of 256 remote controls
and control board programming.
•
Analog limit switch, Digital Encoder or Hybrid system.
•
All programming and settings of the control board are carried out by using TACT-
LED technology or PROG (programmer).
•
Automatic storage of 'O/C' (Opening/Closing) travel time (analog system) or po-
sition by encoder (digital / hybrid system).
•
Output ports for lock and courtesy light modules.
•
Input ports for loose RF receiver, pushbutton, closing and opening photocells.
•
Digital impact sensing with reversion of the gate.
•
'Pedestrian' function (remote control and external pushbutton).
•
Limit switches and pushbutton input ports, configurable as NO (normally open)
or NC (normally closed).
•
The input of the opening and closing photocells is configurable as either NO
(normally open) or NC (normally closed) contacts, pulse output or analog output
(edge sensor).
CHART: LED INDICATIONS
Guide for the functions of the indicator LEDs on the board, when it is not in program-
ming mode, i.e., 'JPROG' jumper open.
LED
SN
• Flashes every 7 seconds: Control board switched on and operational.
LSC
• Lit: Closing limit switch sensor activated.
LSO
• Lit: Opening limit switch sensor activated.
TX
• Lit: Command by registered control remote.
PBU
• Lit: Command by external pushbutton.
CMD
• Lit: Command by loose receiver or by the tacled 'CMD' button.
SF
• Lit: Closing photocell blocked.
• Lit: Empty memory, without remote controls registered.
• Off: Memory with register of remote controls.
MEM
• Flashing: Memory missing or defective. In this case, the control board
will enter BASIC OPERATION MODE.
INDICATION