4. After 5 seconds, the 'SN' LED will flash, indicating that the path has been suc-
cessfully erased.
5. Keep the 'SET' button pressed while the 'SN' LED is still lit.
6. After 10 seconds, the 'SN' LED will flash, indicating that the default factory setting
has been restored.
7. Release the 'SET' button in order to finish the operation.
NOTE:
1. If it is necessary to execute only the operation to erase the path, release the
button (item 5).
2. By performing the factory reset operation, one will also erase the gate path.
3. When performing the operation to erase the path, in the next opening or
closing command, the control board will automatically acquire (memorize) a
new path after the first complete cycle of the gate.
'F/R' JUMPER
It reverses the direction of rotation of the motor, what is opening becomes closing
and vice versa; it also reverses the logic of the limit switch sensors, LSO (opening)
and LSC (closing).
NOTE: Check if in the first command the gate opens. If it is closing, realize
the procedure above.
CHART: SETTING THROUGH 'PROG' (PROGRAMMING TOOL)
PROG: It allows one to set the control board in a more
precise manner.
While the PROG is connected to the control unit, pushbuttons, the 'CMD' button and
loose receivers will be inoperative for motor activation commands on the control
board.
Only by using PROG one can send open / close commands to tha gate, by pressing
the '+' button. One can also use an added remote control, if it is on the main screen
(sensors' status).
By keeping any button of the PROG pressed, after 3 seconds, it will enter the self-repe-
tition mode of the pressed button, which will provide you with more agility to navigate
between the screens or adjustments.