FOG (N.O. by default - adjustable to N.C. with the " I " Jumper)
When the device is ARMED and ready, by bringing the signal (min. 500ms) from the COM
terminal to this input, the 55 secondos shot will start, or, by removing the "T" Jumper the
duration of the shot will be managed by your alarm control panel, with maximum duration
of 55 seconds.
If the shooting time is greater than the ability to generate dry fog, the device will
automatically stop shooting, it will resume as soon as is possible (if the FOG contact is still
active).
When the programmed shot of 55 seconds (T Jumper closed), the forced pause cycle of 5
minutes will follow, during this period, further firing commands will be ignored (to avoid
over-saturation of the room). At the end of the forced pause, if the FOG contact is still active,
the shooting cycle will resume.
With "T" jumper open, the shot is managed by the control panel for a maximum duration of
55 seconds, at the end of this time the appliance will stop dispensing and will remain locked
until the FOG terminal is reset.
The shooting can be stopped at any time by DISARMING the device (ARM).
ATTENTION!!!!!!
NEVER DELIVER FOG IN A CLIMATE ENVIRONMENT
The air conditioning process accelerates the reduction of humidity that "supports" the
substance that creates the fog effect, thus increasing the risk of depositing oily residues on
the surfaces.
If air conditioning is necessary, this risk can be avoided by ventilating the environment or
by stopping the air conditioner until the fog has been completely evacuated.
In any case, the fog must be evacuated from the environment within 60 minutes
OUTPUT: "ARM – HEAT – LEVEL – FAULT – BATTERY"
These "Open Collector" outputs of negative polarity (-12V) are used to communicate the
operating status of the device externally. As well as the ARM-FOG inputs are "N.O." with
the "I" Jumper closed, in the same way it is possible to configure them "N.C." by opening
the "I" Jumper.
It is possible to power external lights or relays from each individual output using, the
positive output taken from the "+ S" terminal, as common.
Attention, the outputs are not measurable with a common tester, you must have a load
(for example: a light bulb or LED + resistance).