Descargar Imprimir esta página

Sagi 3241730 Manual De Uso página 80

Vitrinas verticales refrigeradas

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 90
PARAMETERS OF CONFIGURATION
Parameter
Room probe calibration (the parameter is expressed in eighths of degree)
/1
condenser probe activation (0=off; 1=on)
/3
digital input configuration (0 = open contact, 1 = closed contact)
/6
door open alarm delay time (0 = excluded)
/7
room probe reading
Pr
condenser probe reading
Pc
adjuster hysteresis (differential)
r0
min. operating setpoint selectable
r1
max. operating setpoint selectable
r2
compressor activation delay from device start
C0
min. delay between compr. stop and subsequent start
C2
compressor start cycle time in the event of room probe alarm
C5
C5 % where compr. starts in the event of room probe alarm
C6
defrost interval (0= excluded)
d0
max. defrost duration (0= defrost never activated)
d3
defrosting display (0=actual cell temperature,
d6
1=stopped cell temperature, 2=dEF label)
defrost interval count:
dE
0= actual hours; 1=hours comp. ON; 2= autodeterm.
alarm hysteresis (differential)
A0
min. operating setpoint alarm (0= excluded)
A1
max. operating setpoint alarm (0= excluded)
A2
alarm exclusion from device start
A3
buzzer activation mode for alarm : 0= always; 1= timer-controlled
A4
time limit for buzzer acoustic signal (only if A4 = 1)
A5
temperature alarm exclusion time (only if A1 and/or A2 0)
A6
evaporator fan func. during regular operation (0=OFF; 1=ON; 2=parallel with compressor)
F3
temperature below which the condenser fan turns off
F6
condenser fan differential (relating to F6)
F7
condenser fan func. during regular operation (0=parallel with compr.; 1=ON); also refer to F6 and F7
F8
condenser fan func. during defrost and dripping (0=OFF; 1=ON, 2=ON if Tc≥26°C and OFF if Tc<25°C)
F9
critical temperature for signalling high condensation temperature
FA
critical temperature for high pressure akarm
Fb
Configuration parameters printing enable (0 = disabled)
P0
Sampling time (see also parameter P6)
P1
Selection of temperature probe to be printed (0 = none, 1=chamber probe, 2 = chamber and
P2
evaporator probe)
Payslip heading selection (0 =excluded, 1 = BTV Display Case, 2 = BTS Display Case)
P3
Equipment identification number printing enable (0 = no, 1= yes)
P4
Selection of language for payslip heading (1=Italian, 2=English, 3=French, 4=Spanish, 5=German)
P5
Selection of unit of measure for sampling time (1 = minutes, 2 =hours)
P6
Instrument address (date detected in printing phase if P4 = 1)
L1
Serial port management (o = not utilised, 1 = print)
L2
Baud Rate data transmiss. (1=2400, 2=4800, 3=9600, 4=18200)
L3
Transmission control mode (0 = no parity, 1 = odd, 2 = even)
L4
Parameter
Room probe calibration (the parameter is expressed in eighths of degree)
/1
evaporator probe activation (0=off;1=on)
/2
condenser probe activation (0=off; 1=on)
/3
digital input configuration (0 = open contact, 1 = closed contact)
/6
door open alarm delay time (0 = excluded)
/7
Description
MEASUREMENT INPUTS
COMPRESSOR ADJUSTMENT
COMPRESSOR PROTECTION
DEFROST
ALARMS
EVAPORATOR FAN ADJUSTMENT
PRINT
COMMUNICATIONS MANAGEMENT
Description
MEASUREMENT INPUTS
12
"UNITS +2°C/+10°C"
Default
min
MAX
-24°C
-40
+99
1
0
1
1
0
1
120 sec
0
255
- °C
-
-
- °C
-
-
+3°C
1
15
+2°C
-40
r2
+10°C
r1
+99
1 min
0
240
3 min
0
240
10 min
1
240
50 %
0
100
6 hours
0
99
20 min
0
99
1
0
2
0
0
1
+2 °C
1
15
-2 °C
-40
0
+15 °C
0
+99
120 min
0
240
1
0
1
1 min
0
240
15 min
0
240
1
0
2
20°C
-40
+99
+3°C
1
25
0
0
1
2
0
2
41°C
-40
+99
44°C
-40
+99
1
0
1
60 min
1
60
1
0
2
1
0
2
1
0
1
1
-1
5
1
1
2
1
0
255
1
0
1
3
1
4
0
0
2
"UNITS -20°C/+5°C"
Default
min
MAX
+16°C
-40
+99
1
0
1
1
0
1
1
0
1
120 sec
0
255

Publicidad

loading