Direct voltage measurement
Range
200mV
2V
20V
200V
600V
Overload protection:
200mV range: 250V DC or RMS. AC
The rest range: 600V DC or RMS. AC
Alternating voltage measurement
Range
200V
600V
Overload protection: 600V DC or RMS. AC
Frequency range: 40Hz to 400Hz
Display: Average (effective value of sinusoid)
Direct current measurement
Range
2mA
20mA
200mA
10A
Overload protection:
F1:FF 10AH 600V, 10KA; F2:FF 400mAH 600V, 10KA
When measured current is greater than 2A, the continuous measure-
ment time cannot be more than 2 minutes. Disconnect the current
and wait 10 minutes before making another measurement.
Resolution
100μV
1mV
10mV
100mV
1V
Resolution
100mV
1V
Resolution
1μA
10μA
100μA
10mA
Accuracy
±0.5% of reading, ±3 digits
±0.5% of reading, ±3 digits
±0.5% of reading, ±3 digits
±0.5% of reading, ±3 digits
±0.8% of reading, ±5 digits
Accuracy
±1.0% of reading, ±10 digits
±1.2% of reading, ±10 digits
Accuracy
±1 % of reading, ±3 digits
±1 % of reading, ±5 digits
±1.5% of reading, ±5 digits
±3% of reading, ±10 digits