Problem:
Cause
Filter clogged.
Motor pump damaged.
Membranes clogged.
Solenoid valve blocked.
Problem:
Cause
Filter exhausted.
Appliance contaminated
with bacteria.
Problem:
Cause
The non-return valve is
faulty.
Leak in the hydraulic
circuit.
Problem:
Cause
Fault in the maximum
pressure switch or in the
wiring.
Connections incorrect.
Problem:
Cause
Maximum switch set at too
low a pressure.
Pipe bent or squashed.
Problem:
Cause
Low pressure in the pressurized
tank
Maximum switch set at
too low a pressure.
The appliance produces insufficient water.
Check the pressure downstream of the filter. If it is clogged, replace it.
Switch the appliance off, open the MIX valve fully and contact technical
service.
Switch the appliance off, open the MIX valve fully and contact technical
service.
Switch the appliance off, open the MIX valve fully and contact technical
service.
The treated water has an unpleasant taste.
Change the filter as explained in section 5.4
Contact the technical service to disinfect the appliance.
With the dishwasher switched off, the appliance starts working for a few
seconds.
Contact the technical service.
Contact the technical service.
With the dishwasher in tank-filling phase and the display on, the unit
does not supply osmotized water.
Switch the appliance off, open the MIX valve fully and contact technical
service.
Input/output connections inverted.
With the tap open, the appliance jolts and runs discontinuously.
Switch the appliance off, open the MIX valve fully and contact technical
service.
Make sure the inlet pipes are not bent or squashed.
The outlet pressure is too low
Pre-load the expansion vessel.
Switch the appliance off, open the MIX valve fully and contact
technical service.
Solution
Solution
Solution
Solution
Solution
Solution