Descargar Imprimir esta página

SOMFY Tilt Only 50 WF RTS Central Manual página 18

Ocultar thumbs Ver también para Tilt Only 50 WF RTS Central:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54
EN
2.2. WIRING
Danger
• Cables which pass through a metal wall must be protected and
isolated using a sheath or sleeve.
• Attach cables to prevent any contact with moving parts.
• The drive cable cannot be removed. If it is damaged, return the
drive to the A er-Sales department.
• To ensure electrical safety, this class III drive must be powered by
a "SELV" voltage source (Safety Extra Low Voltage).
Attention
• Leave the drive power supply cable accessible: it must be
possible to replace it easily.
• Do not disconnect the battery or power supply while the drive
is working.
Connect the battery or power supply to the drive's
power supply cable.
2.3. COMMISSIONING
The orange LED flashes continuously in setting mode.
The green LED flashes once when any order is received from a control point.
2.3.1. Pre-programming the RTS control point
Press the Up and Down buttons on the RTS control
point simultaneously: the motorised product
moves up and down and the RTS control point is
pre-programmed in the drive.
18
Copyright
2019 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
Tilt Only 50 WF RTS Central

Publicidad

loading