Descargar Imprimir esta página

BOMANN CL 6045 QC CB Manual De Instrucciones página 101

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 53
Malfunction / Breakdown
The appliance is not responding to signals /
entries.
The display is switched off.
Functions or features are absent from the
display
In this case, switch the appliance off immediately and disconnect the power supply:
Unusual noises during operation
Error in the control board
Blown fuses or broken switch
Spray water or objects in the system
Overheating / burnt cable or plug
Strong odor emanating from the appliance
Error codes in the display
If an error occurs, the following error codes will appear in the display of the interior unit:
NOTE:
Additional error codes can be found in the service manual.
CL6045QCCB_IM
Possible Cause
The remote control is not close enough to the receiver for the interior unit.
There is insufficient voltage remaining in the batteries for the remote control.
Obstacles placed between the remote control and the receiver
Activated LED function
Voltage error
The ECO function is activated (see chapter on servicing) "Energy saving mode (ECO)")
Not all functions or features are shown for each operating mode (see chapter "Operation")
Lamp lights
Blinks once
Blinks twice
Blinks six times
Description of error
Indoor temperature sensor error
Outdoor temperature sensor error
The motor for the interior fan is malfunctioning
101
17.12.20

Publicidad

loading

Este manual también es adecuado para:

Cl 6046 qc cbCl 6047 qc cb