Installation of the Interior Unit and Wall Bushing to the Outside
After you have connected the cooling pipes as well as the drain pipe
for the condensed water in accordance with the directions, proceed as
follows:
1. Using extreme care, lay the pipes, the connecting cable for the exte-
rior unit and the condensed water pipe towards the spot where they
are to be led through the wall to the outside.
2. Bind the condensed water pipes, the connecting cable for the exterior
unit and the condensed water pipe together using vinyl tape and
then cover everything tightly using insulating tape (not included in
delivery).
CAUTION:
• Ensure that the pipes are impermeably sealed to avoid moisture
damage and mildew build-up in the walling.
• Make sure all exposed tubular parts have been sufficiently isolated.
3. Drill a hole with a diameter of 57 mm and an incline / gradient of
5 - 7 mm. (Image 2)
NOTE:
Drill this with a slight incline of 5 - 7 mm toward the outside, to en-
sure that the condensed water is able to drain. In any case, make
sure that there is an incline over the entire length of the condensed
water pipe in the direction of the opening in the wall.
4. Insert the hole-cover.
5. Guide the insulated pipes, the connecting cable for the exterior unit
and the condensed water pipes through the opening in the wall.
• Before connecting the pipes, decide where you want to place the
exterior unit and take care to ensure that there is enough room in the
location you have chosen for maintenance work to be performed at a
later time. (Observe the minimum distances)
• Put the protective caps (included in delivery) on the stand and fasten
these in the appropriate places.
• Use exceptionally sturdy screws / bolt anchors and bear in mind also
the weight of the appliance, in order to prevent vibrations caused by
operation from loosening the connection over time. The unit must be
installed in accordance with the applicable safety regulations.
Condensed Water Drain Pipe for the Exterior Unit
Condensed water and ice which build up in the exterior unit due to heat
generation can be drained by means of the condensed water pipe.
1. Fasten the supports for the condensed water drain pipe in the 25 mm
opening designed therefor.
2. Connect the supports for the condensed water drain pipe to the con-
densed water pipe and ensure the flow is properly controlled in order
to avoid moisture damage.
94
CL6045QCCB_IM
NOTE:
After installing the pipes, seal the hole in the wall through which the
pipes have been passed so that it is airtight as well as watertight.
6. Fasten the interior unit securely to the upper part of the wall mounting
plate.
7. Press the lower part of the interior unit firmly against the wall mount-
ing plate until it rests firmly.
Installation of the Exterior Unit
Remove the connector cover (15) on the right side of the appliance. The
associated diagram can be found on the rear side. See diagram.
1. Connect the power supply cable for the interior unit to the terminal
strip.
2. Carefully attach the power supply cable for the exterior unit using the
cable connecting clamps.
3. Make sure that the cables have been properly attached. Be sure that
the grounding has been correctly installed.
4. Place the protective cover back on the appliance.
Electrical Connection (Exterior Unit)