Descargar Imprimir esta página

MSW Motor Technics FIPT-01 Manual De Instrucciones página 5

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
EN
TECHNICAL DATA
Parameter description
Parameter value
Product name
Fuel injection pressure tester
Model
MSW-FIPT-01
Suitcase dimensions
340 x 292 x 566
[mm]
Weight [kg]
4,1
Pressure gauge range
0-100 PSI/7 Bar
For most gasoline fuel
systems of modern passenger
cars and commercial vehicles
Adapter
as well as Bosch K-Jetronic /
Continuos Injection System
(CIS)
1. GENERAL DESCRIPTION
The user manual is designed to assist in the safe and
trouble-free use of the device. The product is designed
and manufactured in accordance with strict technical
guidelines,
using
state-of-the-art
technologies
components. Additionally, it is produced in compliance
with the most stringent quality standards.
DO NOT USE THE DEVICE UNLESS YOU HAVE
THOROUGHLY READ AND UNDERSTOOD THIS
USER MANUAL.
To increase the product life of the device and to ensure
trouble-free operation, use it in accordance with this user
manual and regularly perform maintenance tasks. The
technical data and specifications in this user manual are
up to date. The manufacturer reserves the right to make
changes associated with quality improvement.
LEGEND
Read instructions before use.
The product must be recycled.
WARNING! or CAUTION! or REMEMBER!
Applicable to the given situation (general
warning sign).
Wear protective goggles.
Wear protective gloves.
ATTENTION! Fire hazard - flammable materials!
WARNING! Toxic substances, danger of
poisoning!
PLEASE NOTE! Drawings in this manual are for
illustration purposes only and in some details may
differ from the actual machine.
The original operation manual is in German. Other
language versions are translations from German.
2. USAGE SAFETY
ATTENTION! Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in an electric shock, fire and/
or serious injury or even death.
8
U S E R M A N U A L
The terms "device" or "product" are used in the warnings
and instructions to refer to FUEL INJECTION PRESSURE
TESTER. Prevent the device from getting wet. Risk of electric
shock! Do not exceed the maximum permissible operating
pressure!
2.1. SAFETY IN THE WORKPLACE
a)
Make sure the workplace is clean and well lit. A messy
or poorly lit workplace may lead to accidents. Try
to think ahead, observe what is going on and use
common sense when working with the device.
b)
If you are unsure about whether the product is
operating correctly or if you find damage, please
contact the manufacturer's service centre.
c)
Only the manufacturer's service centre may make
repairs to the product. Do not attempt to make repairs
yourself!
d)
Children or unauthorised persons are forbidden to
enter a work station. (A distraction may result in loss
of control over the device).
e)
Use the device in a well-ventilated space.
f)
Do not cut off the supply of compressed air by
crushing or bending pressure hoses.
g)
Please keep this manual available for future reference.
and
If this device is passed on to a third party, the manual
must be passed on with it.
h)
Keep packaging elements and small assembly parts in
a place not available to children.
i)
Keep the device away from children and animals.
j)
If this device is used together with another equipment,
the remaining instructions for use shall also be
followed.
REMEMBER! When using the device, protect children
and other bystanders.
2.2. PERSONAL SAFETY
a)
Do not use the device when tired, ill or under the
influence of alcohol, narcotics or medication which
can significantly impair the ability to operate the
device.
b)
The device can be handled only by physically fit
persons who are capable of handling it, properly
trained, familiar with this manual and trained within
the scope of occupational health and safety.
c)
Use personal protective equipment as required
for working with the device, specified in section 1
(Legend). The use of correct and approved personal
protective equipment reduces the risk of injury.
d)
The device is not a toy. Children must be supervised to
ensure that they do not play with the device.
2.3. SAFE DEVICE USE
a)
Make sure the pressure line is disconnected before
attempting any adjustments, accessory replacements
or doing any work on the device. Such a preventive
measure reduces the risk of an accident.
b)
When not in use, store in a safe place, away from
children and people not familiar with the device who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
c)
Keep the device in perfect technical condition. Before
each use check for general damage and especially
check for cracked parts or elements and for any other
conditions which may impact the safe operation of the
device. If damage is discovered, hand over the device
for repair before use.
Rev. 24.01.2022
d)
Keep the device out of the reach of children.
e)
Device repair or maintenance should be carried out by
qualified persons, only using original spare parts. This
will ensure safe use.
f)
When transporting and handling the device between
the warehouse and the destination, observe the
occupational health and safety principles for manual
transport operations which apply in the country
where the device will be used.
g)
Clean the device regularly to prevent stubborn grime
from accumulating.
h)
Before each use ensure the nozzle is correctly installed
in the device and that the hose is correctly attached
and undamaged.
i)
Do not carry or hang the device by the pressure line.
j)
The device is not a toy. Cleaning and maintenance may
not be carried out by children without supervision by
an adult person.
k)
It is forbidden to interfere with the structure of
the device in order to change its parameters or
construction.
l)
Keep the device away from sources of fire and heat.
ATTENTION! Despite the safe design of the device
and its protective features, and despite the use of
additional elements protecting the operator, there is
still a slight risk of accident or injury when using the
device. Stay alert and use common sense when using
the device.
3. USE GUIDELINES
The product is intended for measuring pressure in the fuel
system of gasoline engines equipped with mechanical or
electronic injection. The product is intended for professional
use.
The user is liable for any damage resulting from
unintended use of the device.
3.1. DEVICE DESCRIPTION
ATTENTION! This product's view can be found on the
last pages of the operating instructions (pp. 35).
No.
Intended use
1
Manifold with quick coupler8V1
2
Adapter for small Schrader valve (Ford) - 7/16''-20
(F)
3
Connecting hose for GM TBI—M16X1.5 (M) +
M16X1.5 (M)
4
Connecting hose with a coupler for the Bosch CIS
/ Jetronic system-- M12X1.5(M) + M12X1.5 (M)
5
5/8 '' - 18 and M16X1.5 (F) universal adapter x2 pcs.
6
M16x1.5 female adapter on one side and pipe
connection 3/8 on the other, x2 pcs.
7
M14x1.5 female adapter on one side and 3/8
pipe connection on the other
8
M10x1.0 (M) -M12x1.5 (M) adapter with O-ring
9
Adapter M12X1.5(M)+M8X1.0(M) with O-ring
10
Adapter M16X1.5 with connector 3/8 and O-ring;
x2 pcs.
Rev. 24.01.2022
EN
11
Adapter-M14X1.5 with connector 3/8, and O-ring;
x2 pcs.
12
Adapter M12X1.5 (M) +M10x1.0 (F)
13
Adapter M12X1.5 (M)+M8X1.0 (F)
14
M12X1.25(M) with a washer
15
M12X1.5(M) with a washer
16
M10X1.0(M) with a washer
17
M8X1.0 (M) with a washer
18
M6X1.0 (M) with an O-ring
19
M12X1.5 (M) + M8X1.0 (M) adapter x2 pcs. with
an O-ring
20
M14X1.5 (F) + M14X1.5 (M) connection
21
M16X1.5 (M) elbow x 4 pcs. in two sizes: 65mm
and 85mm;
22
Manifold with a plug for a quick coupler
23
PSI / bar pressure indicator
24
Adapter for standard Schrader valve
25
Hoses Ø15x Ø8mm, length 85mm 3 pcs.
Ø17x Ø9mm, length 85mm 3 pcs.
26
Adapter-Ford CFI BYEYA D7.89>PA12<
27
300psi hose, L-85mm, Ø12x Ø6.5mm
Screw clamp bands x 4 pcs.
28
Copper washers (Ø17.5 / Ø16.3 / Ø14.3 /
Ø12.2mm)
Paper pads (Ø16.5 / Ø14.3 / Ø19.5mm)
O-ring (Ø12 / Ø10mm)
Plug x 2 pcs.
Plastic valve stem x 2 pcs.
29
Ø7mm hose, wall thickness -0.9mm
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The ambient temperature must not exceed 45°C and the
relative humidity should not exceed 85%. Only use the
device in well-ventilated areas. Keep the device away from
any hot surfaces. Keep a type B fire extinguisher within
reach.
3.3. DEVICE USE
3.3.1 CHECKING VEHICLE COMPONENTS
Before testing the fuel system pressure, first check the
condition of the following components:
A.
Fuel system:
Are there any damaged or loose fuel lines (metal or
rubber)?
Is there enough fuel in the tank?
Is there any dirt or water in the fuel?
Are all the fuses / relays of the fuel system OK?
Is the tank venting system working properly?
Is the fuel filler cap tight and closed well?
B.
Electrical system
Does the engine start easily? If not, check the ignition.
Is the OBD system displaying any error messages or is
the "Engine Check" indicator off after starting?
9