Descargar Imprimir esta página

Metabo TDP 7501 S Manual Original página 12

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
ENGLISH
4.2
Fixing the float switch cable
3
Note:
Fix the float cable such that the distance be-
tween the cable holder and the float switch is
at least 100 mm.
Clip the float switch cable as illustrated in
the cable holder (13). Ensure that the ca-
ble is secured in the cable holder in such
a way that it cannot slip.
A
Caution!
The float switch cable may be damaged.
Never pull on the float switch cable to
change its position in the cable holder!
Remove the cable from the cable holder and
clip it back in the cable holder in the desired
position.
12
4.3
Installation instructions
Space required: approx. 50 x 50 cm.
In order for the float switch to function
properly it must be able to move freely.
Submerge the pump to no more than the
maximum immersion depth specified in
the technical data.
Install the pump such that the suction in-
lets cannot be blocked by foreign objects.
If necessary place the pump on a support
surface.
Ensure sufficient upright stability.
B
Risk of electric shock from severed
cables!
Do not lift or transport the pump by the ca-
bles or the discharge hose! The cables and
the discharge hose are not designed to with-
stand the tensile stress produced by the
weight of the pump.
4.4
Installing the pump
1. Submerge pump at a slight angle to avoid
creating an air cushion on the underside,
13
which would prevent priming. Once the
pump is submerged, it can be placed up-
right.
2. Lower pump to the bottom of the fluid con-
tainer.
Use a strong rope fastened to the lifting
eye to lower the pump.
The pump can also be operated when
suspended by a rope.
3. Before operating the pump again ensure
that the pump line has been completely
emptied. When doing so vent the pump if
necessary.
5.
Operation
5.1
Switching ON and OFF
After you have connected the pump to the
mains it will be switched on (14) and off (15)
automatically by the float switch. The point in
time at which switching occurs depends on
the water level.

Publicidad

loading