Descargar Imprimir esta página

tau K580M Guía Para La Instalación página 14

Ocultar thumbs Ver también para K580M:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
8 - 9
STOP
SENSITIVE
10 - 11
EDGE
10 - 12
PHOTOCELLS
RX
13 - 14
PHOTOCELLS
13 - 15
PHOTOCELL
GATE OPEN
16 - 17
LED
2
RADIO
nd
18 - 19
CHANNEL
20 - 21
AERIAL
LIMIT
M1
SWITCH
M2
ENCODER
FS1 - FS2
CAPACITOR
230V AC
M3
MOTOR
LOGIC ADJUSTMENTS
TRIMMER
FR.
Motor torque adjustment. The trimmer is set to provide sufficient thrust to work the gate
without exceeding the limits established by current standards (EN 12453). Turning the
trimmer clockwise (+) increases the motor torque, turning it anticlockwise (-) re-
duces it.
RALL.
Deceleration adjustment: from 0 to 150 cm before the limit switch;
Note: the automation must perform a complete opening and closing manoeuvre
before setting the deceleration.
14
STOP pushbutton input (Normally Closed contact);
SENSITIVE EDGE input (resistive sensitive edge or fixed safety
edge); Works only when the gate is opening; temporarily stops the
gate and partially closes it by about 20 cm in order to allow the
obstacle to be removed. (10=Common);
NOTE: if a resistive sensitive edge is connected, set dip-
switch no. 12 to ON;
If a fixed safety edge with NC contact is connected, set dip-
switch no. 12 to OFF;
input for PHOTOCELLS OR SAFETY DEVICES active during
closure (Normally Closed contact); They stop the gate during
closing and totally reopen it; they temporarily stop the gate during
opening in order to allow the obstacle to be removed (if dip switch
n° 3 set to ON), (10= Common).
device, connect all the NC contacts IN SERIES.
Note: the photocell transmitter must always be supplied by
terminals no. 13 - 15, since the safety system test (phototest)
is carried out on it. To override the testing of the safety system,
or when the photocells are not used, set dip-switch no. 6 to
OFF. If the phototest is not successful, the control unit will
not operate.
24 Vac 10 W output to POWER THE RXs AND ANY OTHER TXs OF
PHOTOCELLS THAT ARE PRESENT, EXTERNAL RECEIVERS,
etc.; connect a max. of 3 pair of photocells.
13= 0 Vac, 14= 24 Vac;
24 Vac 10 W POWER output for PHOTOCELL TX (only the one
TX
that performs the Phototest) max. no. 1 photocell transmitter.
13= 0 Vac, 15= 24 Vac;
GATE OPEN LED output 24 Vac - max. 3 W; during opening of
the gate the warning light flashes slowly, when the gate is open it
remains steadily illuminated and during closure it flashes twice as
fast. 16= 0 Vac, 17= 24 Vac;
2nd RADIO CHANNEL output (its operation depends on dip-
switches nos. 7 - 8) to be used for opening/closing another gate,
for controlling garden lights or for the "ZONE LIGHTING" function;
Warning: to connect other devices to the 2nd Radio Channel
(area lighting, pumps, etc.), use an additional auxiliary relay.
433,92 MHz built-in RX antenna input;
20= EARTH, 21= SIGNAL;
quick coupling for LIMIT SWITCH connection (Normally Closed
contacts). Orange= ClosureLimitSwitch (CLS),
red= OpeningLimitSwitch (OLS), grey= Common (COM);
quick coupling for ENCODER connection. Blue= 0 Vdc (GND),
brown= 5 Vdc (+5V), white= ENCODER SIGNAL (ENC);
faston for motor start-up CAPACITOR connection;
quick coupling for 230 Vac single-phase MOTOR connection
common= BLUE (M-COM); closure= BROWN (M-CL); opening=
BLACK (M-OP).
K580M
If there is more than one safety

Publicidad