T.C.A.
Automatic closing time adjustment from 5 to 120 seconds.
Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
OPENING
3
PHOTOCELLS
OPERATION
NO
4
REVERSE
PRE-
5
FLASHING
PHOTOCELL
6
TEST
7 - 8
2nd RADIO CHANNEL operation (terminals no. 18 - 19)
Dip 7 Dip 8 Function
Off
Off
Off
On
On
Off
On
On
DECELE-
9
RATION
OPENING
10
DIRECTION
SETUP
11
ENCODER*
SENSITIVE
12
EDGE
*
In the event of 5 consecutive activations (during the same closing manoeuvre) of the encoder (ob-
stacle detection), the control opens completely on the next manoeuvre. To reset, the automation must
complete a manoeuvre (opening and then closing); otherwise the end stop search process will be
repeated after each activation of the encoder.
after opening, the gate automatically closes when the delay set on the
On
T.C.A. trimmer expires.
Off
automatic closing disabled.
with automatic closing enabled, a sequence of open/close commands
On
causes the gate to OPENCLOSE-OPEN-CLOSE etc (see also dip
switch 4).
in the same conditions, the same command sequence causes the
Off
gate to OPEN-STOP-CLOSESTOP-OPEN-STOP (step-by-step).
during opening, the photocell cuts in to stop the gate until the obstacle
On
is removed. When the obstacle is removed the gate resumes opening;
Off
during opening, the photocell does not cut in.
NO-REVERSE function activated; the gate ignores the closure
On
commands during opening and reversal of movement occurs only
during closure;
the open-close pushbutton reverses the direction of movement of the
Off
gate even while it is opening.
On
the pre-flashing function enabled.
Off
the pre-flashing function disabled.
On
the "photocell test" function is enabled;
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
Gate contact open: The contact activates on opening the gate and remains
active during the open time, during the TCA and during reclosure. It deactivates
once the gate has completed its closure movement.
Bistable function active: the radio control impulse causes the contact to activate
and remain active until the subsequent impulse.
Monostable function active for 2 sec.: the radio control impulse causes the
contact to activate and remain active for 2 sec.
Monostable function active for 180 sec.: the radio control impulse causes the
contact to activate and remain active for 180 sec.
the deceleration function is on and can be adjusted by means of the
On
RALL trimmer (see "How to set the soft-stop");
Off
the deceleration function is off;
On
left-hand leaf opening function;
Off
right-hand leaf opening function;
ENCODER enabled: encoder obstacle detection function activated
On
(use the trimmer FR to adjust the sensitivity to obstacles);
Off
ENCODER disabled;
On
RESISTIVE SENSITIVE EDGE (terminal no. 11);
Off
FIXED EDGE (NC contact – terminal no. 11).