CORD SETS AND RECEPTACLES
Use only high quality, weGinsulated,
extension cords
with the generator's 120 Volt electrical receptacles.
Check the ratings of all extension cords before you
use them. Extension cord sets used should be rated
for 125 Volt AC loads at 20 Amps or greater for most
electrical devices. Some devices, however, may not
require this type of extension cord. Check the owner's
manuals of those devices for the manufacturer's
recommendations.
Keep extension cords as short as possible, preferably
less than 15 feet long, to prevent voltage drop and
possible overheating of wires.
CAUTION
]
• NEVER
attempt
to power
a device
requiring
more
amperage
than generator
or receptacle
can supply,
• DO NOT overload
the generator,
See "Don't
Overload
Generator",
240 Volt AC, 50 Amp Receptacle
Use a NEMA 14-50 plug with this receptacle. Connect
a 4-wire cord set rated for 250 Volt AC loads at
50 Amps to the plug.
_------240
Volts AC --
Frame_
Y (Hot)
X (Hot)
120 Volts
--
AC
W (Neutral)
NEMA 14-50
Use this receptacle to operate 240 Volt AC, 50 Amp,
60 Hz, single phase loads requiring up to 10,000 watts
(10.0 kW) of power. The outlet is protected by a
45 Amp push-to-reset
circuit breaker.
1201240 Volt AC, 30 Amp,
Locking
Receptacle
Use a NEMA L14-30 plug with this receptacle.
Connect a 4-wire cord set rated for 250 Volt AC loads
at 30 Amps (or greater). You can use the same 4-wire
cord if you plan to run a 120 Volt load.
4-Wire Cord Set
J
1
NEMA L14-30
(Neutral)
Y (Hot)
_
X (Hot)
Ground (Green)
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts of power at
30 Amps for 120 Volts; 7,200 watts of power (7.2 kW)
at 30 Amps for 240 Volts. The outlet is protected by a
30 Amp push-to-reset
circuit breaker.
120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect
a 3-wire cord set rated for 125 Volt AC loads at
30 Amps to the plug.
3-Wire Cord Set
NEMA L5-30
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 3,600 watts
(3.6 kW) of power at 30 Amps. The outlet is protected
by a 30 Amp push-to-reset
circuit breaker.
13