Descargar Imprimir esta página

Monarch Industries Black lynx 636004 Manual Del Usuario página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

CARE AND MAINTENANCE________________
AFTER USE: Clean out the drum with water. If cement has dried to the inside of mixer, tap the
outside of the drum with a rubber or plastic mallet. Dump mixer to empty dried cement from drum
(DO NOT use a steel hammer to dislodge dried cement from mixer).
Lightly grease all moving parts.
Keep the motor assembly clean and free of build up. Wipe the on/off switch assembly and motor with a
lightly dampened cloth. DO NOT spray water directly onto motor. Protect motor assembly from rain. Store
mixer indoors.
TROUBLESHOOTING______________________
Problem
Probable Cause
Motor trips
1. Motor overloaded
out repeatedly
on reset.
2. Extension cord too long.
3. Extension cord too light
a gauge.
Mixer is
1. Blown Fuse
plugged in,
2. Tripped Circuit
but does not
3. Disconnected plug
start (motor is
4. Corroded plug
not humming)
5. Tripped manual reset
6. Defective motor
7. Loose connection in motor
Motor is
1. Starting under too much load
humming
2. Motor too cold
In the event of overheating and your motor shuts down, turn off the On/Off switch and
unplug the unit for 15 minutes. After the cooling period, plug in the unit and press the
Manual Reset Thermal Protector button, then turn the On/Off switch to on.
Corrective Action
1. Empty mixer. Press manual reset button located on the
motor.
CAUTION: Multiple resets may burn out the motor and void
warranty, contact factory
2. Refer to power cord safety (page 4).
3. Refer to power cord safety (page 4).
1. Replace
2. Reset
3. Reinstall
4. Clean prongs
5. Reset
6. Contact factory
7. Unplug motor, open motor cover, and check connections
1. Empty load, start mixer empty, refill mixer
2. Motor will not start properly below 32°F (0°C). Press reset,
start motor again. This may have to be repeated several times
until motor warms up.