Humidity setting
Auto dehumidifying mode:
When "CO" (continuous) operation is set to dehumidify, the
dehumidifier will continue to operate regardless of the humidity
level.
If the indoor humidity is higher than or equal to 3% or more of the
set humidity, the compressor and fan will run. The indicator light of
the compressor will be on.
After the humidity in the room is dehumidified, when the humidity
drops below 2% of the set humidity, the compressor is turned off
and the dehumidification is stopped. The indicator lamp (OK lamp)
that reaches the humidity is on.
If the dehumidifier stops dehumidifying and the humidity in the
room rises above or equal to 3% or more of the set humidity, if the
compressor has passed the three minute protection status, the
compressor will start dehumidifying.
According to the above cycle operation, the indoor humidity can be
maintained at the set humidity.
Comfort (shows "AU") function:
Below 5ºC at room temperature, the dehumidifier stops;
If 5ºC ≤ room temperature ≤ 20ºC, automatic selection set 60%
humidity;
If 20ºC<room temperature ≤27ºC, automatically select setting
55% humidit;
If Room temperature> 27ºC, automatic selection set 50% humidity.
Drying function: (CLOTH light):
When this function is enabled, the dehumidifier will continue to
operate (compressor, fan operation) regardless of the humidity
level when the "CO" (continuous) operation dehumidifies.
The wind speed is locked at high speed and cannot be adjusted.
Fan:
During the fan mode, the compressor does not work.
You can select two operating mode: high and low wind. Important:
Humidity setting button cannot be pressed in fan mode.