CLEANING AND MAINTENANCE
· Unplug the appliance before cleaning.
· Empty water tank to avoid odor occurring when not in use.
· After few days operation, dust and dirt may reserve in water tank. It is recommended to change
water and clean water tank frequently.
· After long time operation, the filtration mesh becomes clogged with dust and dirt, which will
greatly affect the unit's performance. It is recommended to clean the filtration mesh frequently.
· Use a soft cloth to clean the appliance. Do not use solvents or harsh chemicals. Never use direct
water. Do not allow water to come in contact with the control panel.
· Do not clean with metal sourcing pads. It may scratch the surface or cause electrical shock.
FILTER
Use a soft brush, and if necessary some water and mild detergent.
When everything is dry, place each filter in corresponding position.
OUTER CASING
The surface of the appliance can be cleaned using wet cloth but do no rinse directly with water.
END OF SEASON STORAGE
Switch off and unplug the unit.
Clean or change the filter.
Turn on the unit for a while, so the inside can dry out completely.
It is recommended to store the unit in it's original carton. Do not stack heavy objects on top of the
unit.
TROUBLESHOOTING
Problem
-Operating screen
Stays dark
-Display is normal but
without air flow or the
air speed is too low
-Motor does not
Respond to control
Panel
-Water leaking From
drain valve
-Air diffuser/swing
Function not working
-Water drops splash
Out df the air diffuser
Cause
-No power
-Main control board failure
-Fuse is blown
-Panel failure
-The fan is jammed
-Cooling pad or dust filter is blocked
-Fan is distorted
-Main control board failure
-Main control board Failure
-Panel failure
-Drain valve is loose
-Dirt in valve
-Svnchronous motor is burnt ou
-Crankshaft is broken
-Water pipe has come loose
EN
Solution
-Check unit is plugged in
-Change control board
-Change fuse
-Change panel
-Check to ensure there is nothing
preventing free rotationof the fan
-Clean the cooling pad and dust filter
-Change the fan
-Change the main control bpard
-Change the main control board
-Change panel
-Tighten drain valve nut
-Clean drain valve
-Change synchronous motor
-Change crankshaft
-Check water pipe to top of filter pad
and reattach or tighten as necessary
13