INSTALLATION INSTRUCTIONS
4. Inlet wire mode 1: use the installation template to mark the fixed bracket installation hole position.
Inlet wire mode 2: use the installation template to mark the position of the fixing bracket installation hole and
the cable entry hole.
Note 1: Inlet wire mode 2 which need to pay attention to the correct direction of the installation template.
Note 2: Make sure that the installation template itself is level when the position is marked.
Note
3:Refer to Installation template.
5. Punch holes according to the punching information prompted by the installation template, and ensure that
the punch positions are accurate.
(1). Fixed bracket mounting hole has a diameter of 6mm and a depth of about 35mm.
(2). Inlet wire mode 2, diameter of the cable entry hole needs to be defined according to the actual cable
selection, However, it is recommended that the maximum opening diameter should not be bigger than 24mm.
Caution: The edge of the wall opening needs to be repaired, and it must not be a sharp edge to prevent the
incoming wire from being cut.
6. Fixing bracket installation hole inner - insert wall plugs, and use attachement screws(ST4.2*32) fixing fixed
bracket to the mounting surface and ensure the screws are fastened well.
Note: If the screws are not fastened well, the fixing bracket may become loose and may interfere with the
installation of the housing.
7. According to the size and position below, open the power cable hole on the shell.
NOTE 1: Inlet wire mode1, open hole size must be accurate, and the hole diameter is 24mm(for the single
phase) or 28mm (for the three-phase).
NOTE 2: Inlet wire mode 2, open hole size must be accurate, and the hole diameter is 18mm.
WARNING: Remove burrs around the hole to prevent affecting the seal level.
WARNING: Do not damage internal components, especially internal wiring, when drilling the hole.
8. Clean and remove all the debris that has fallen into the shell due to the punching.
9. Inlet wire.
Punch hole position
Inlet wire mode 1
Drilling direction
50mm
Punch hole position
Inlet wire mode 2
Drill position
Drilling
direction
10
Wiring cap
In
Cable
fig. 4