Installation
Place the adhesive on the back of both the alarm and the magnetic sensor and
attach them to the door, taking special care that the indicated triangles face each
other at the same height, at a distance of no greater than 15 mm between them.
Left-opening door
Low power warning
When the battery voltage is below 2.1 V, it will emit a beep. When this happens,
replace the batteries as soon as possible.
Changing the batteries
• Release the rear cover of the alarm, sliding it upwards until it is
completely uncovered to access the electronic system:
• Place 2 AAA batteries for the alarm operation.
Specifications
Frequency
Ambient humidity
Operating temperature
Decibelios
Battery type (alarm)
Battery type (remote control)
Range of remote control B (without barriers)
Alarm battery life at rest
Remote control battery life at rest
Alarm weight
Remote control weight
Alarm dimensions
Magnetic senso
Remote control dimensions
15mm
Right-opening door
433,92 MHz
<90%
-10ºC to 60ºC
110 db
2 x AAA
1 x CR2032
approx.15 mts
1 year
1 year
90x43x13mm
45x13x13mm
61x33x10mm
En
60g
15g
17