1. Pull the water filter out.
2. Clean the water filter under running
water.
3. Re-insert the water filter into the wa-
ter connection.
Troubleshooting guide
DANGER
Risk of injury due to inadvertently
starting up device and also due to
electric shock.
Switch off the device immediately and
unplug the mains plug before perform-
ing work.
Fault
Device does not
start
Device not build-
ing up pressure
Pump leaking
Up to 3 drops of
water per minute
are permissible.
Pump knocking
Índice de contenidos
Remedy
Reset GFCI plug.
Check the power cable for damage.
Check the mains voltage.
If the device overheats:
a Set the power switch to "0".
b Allow the device to cool for at least 15 minutes.
c Set the power switch to "1".
Contact Customer Service in case of electrical faults.
Fit the standard nozzle.
Clean / replace the high-pressure nozzle.
Vent the device.
Clean the water filter.
Clean all inlet pipes to the pump.
Check the water supply volume.
In case of more serious leaks, have the device checked by
Customer Service.
Clean the water filter.
Check the water supply line for leaks.
Vent the device.
Contact Customer Service if necessary.
Have electrical components checked
and repaired by authorised Customer
Service.
In case of any malfunctions not men-
tioned in this chapter, contact Custom-
er Service when in doubt or when you
have been explicitly advised to do so.
agua ................................................... 18