04. Technical details
Unit featuring a pneumatic cylinder that activates the hydraulic device which provides the
pressure necessary to spray the product.
The unit is supplied with a suction probe, which is inserted directly in the container of the product
to be applied.
Dimensions
(with trolley)
Dimensions
(with wall)
Net weight
(with trolley)
Pressure ratio
Pneumatic cylinder
Free flow
(60 cycles/min)
Flow per cycle
Maximum air inlet
pressure
Maximum fluid outlet
working pressure
Air consumption
at 60 bar (870 psi) and
2.4 CPM
Air Inlet
Product outlet
Temperature
operating range
Carriage
bracket or
wall bracket
Directives and regulations
Directive Machine
ATEX regulation
(*) Non electric equipment in explosion hazard areas (ATEX) must have the earthing connections and/or
static-free feed hoses.
HT pneumatic pumps Technical Data
HT 10
52.6 x 57.6 x 87.5 cm /
54.3 x 35.9 x 51.6 cm /
41 Kg / 90.4 lbs
10:1
Ø 135 mm.
9.75 L/min.
2.14 gpm
2.58 US gpm
105.55 c.c. / 0.023 g/min. / 0.028 imp Gal
66 bar
957 psi
16.71 L/min.
3.68 gpm
4.41 US gpm
from -10 to +60
Optional
2006/42/UE
Community directive complied with 2014/34/UE
Explosive atmosphere (Atex):
ENGLISH
HT 15
20.7 x 22.7 x 34.4"
21.4 x 14.1 x 21.3"
42 Kg / 92.5 lbs
15:1
Ø 150 mm.
9.75 L/min.
2.14 gpm
2.58 US gpm
6 bar / 87 psi
82 bar
1,189 psi
13.85 L/min.
3.05 gpm
3.66 US gpm
Barb 13 mm.
BSP 3/8"
o
C / from 14 to 140
Absorption
probe
II 2G T4 x (*)
HT 25
45 Kg / 99.2 lbs
25:1
Ø 200 mm.
9.75 L/min.
2.14 gpm
2.58 US gpm
148 bar
2,146 psi
14.96 L/min.
3.29 gpm
3.95 US gpm
o
F
OK (included)