EN
PROBLEM
Motor won't start
Motor turns without
pumping water
Flow rate insufficient
Tripped motor
oveload cutout
If these precautions aren't followed, the
pumps can be damaged and the
warranty will have no effect.
DECLARATION OF
CONFORMITY
We declare under our
exclusive responsibility, that
the product SELF-PRIMING JET
PUMP with code VIBAF750A;
VIBAF1100A; VIBAF1500A, meets
the following standards or
standardization documents:
EN ISO 12100:2010, EN
809:1998+A1:2009+AC:2010, EN
60204-1:2006+A1:2009+AC:2010,
EN 60335-
1:2012+A11:2014+AC:2014, EN
62233:2008+AC:2008, EN 60335-2-
41:2003+A1:2004+A2:2010, EN
60034-1:2010+AC:2010, EN 55014-
1:2006+A1:2009+A2:2011, EN
55014-2:2015, EN 61000-3-2:2014,
EN
61000-3-3:2013, according to the
determinations of the directives:
2014/30/EU - Electromagnetic
Compatibility Directive;
2014/35/EU - Low Voltage
Directive;
2006/42/EC - Machinery
Directive.
2011/65/EU – RoSH Directive.
CAUSE
No power
Impeller stuck
Clogged filter
Excessive intake height
Air in intake
Clean filter
Intake height at limit
Filter partially clogged
Impeller blocked
Overheated motor
Impeller stuck
S. João de Ver,
20th of March of 2019.
Central Lobão S. A.
Responsible for the Technical File
19
SOLUTION
Check connections and voltage values
See section on maintenance
Move pump closer to water outler level
Check intake pipe is airtight
Make sure foot valve is immersed by at
least 60 cm
Pump needs to be primed again
Check intake height
Clean foot valve and, if necessary, whole
intake pipe
Disassemble pump and carefully clean
pump body and impeller
Check voltage and ventilation
Release impeller (see section on mainte-
nance)
WARRANTY TERMS
The warranty of this machine is two
years from the date of purchase. You
should, therefore, keep your
proof of purchase during this period of
time. The warranty covers any
manufacturing defect in material
or operating, as well as parts and
work needed for their recovery.
Excluded from the warranty
the misuse of the product, any repairs
carried out by unauthorized persons
(outside the service center of the brand
VITO) as well as any damage caused
by the use of it.
11