9.2.
Programming the settings
The operating parameters, modifiable using the
keypad, are divided into two types: frequent (type
F) and configuration (type C). Access to the latter
is protected by password (default= 22) to prevent
accidental or unauthorised modifications.
Accessing the type F parameters:
Press the
button for more than 3 s (if
there are active alarms, mute the buzzer). The
display shows the parameter code 'PS'
(password);
use the
and
parameters. The LED corresponding to the
category of parameters will be on (see Table).
press
to display the value associated
with the parameter;
increase or decrease the value using the
and
button respectively;
press
to temporarily save the new value
and display the parameter again;
repeat the procedure for any other parameters
that need to be modified;
press the
button for more than 3 s to
permanently save the parameters and exit the
parameter setting procedure.
buttons to scroll the
Accessing the type C parameters:
Press the
button for more than 3 s (if
there are active alarms, mute the buzzer), the
display shows the parameter code "PS"
(password);
press the
button to access the password
setting;
use the
and
numbers until displaying "22" (password to
access the parameters);
press the
button to confi rm the
password;
use the
and
parameters. The LED corresponding to the
category of parameters will be on (see Table)
press
to display the value associated
with the parameter;
increase or decrease the value using the
and
button respectively;
press
to temporarily save the new value
and display the parameter again;
repeat the procedure for any other parameters
that need to be modified;
press the
button for more than 3 s to
permanently save the parameters and exit the
parameter setting procedure.
if no button is pressed for 60 s, all the
Warnings :
changes made to the parameters, temporarily
saved in the RAM, will be cancelled and the
previous settings restored.
If power is disconnected from the instrument
before saving the settings (pressing the
button for 3 s), all the changes made to the
parameters and temporarily saved will be lost.