Descargar Imprimir esta página

Pentair LTHH Serie Manual Del Propietário página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

ELECTRICAL
WIRING
Install, ground, wire and maintain this pump in accordance
with electrical code requirements. Consult your local building
inspector for information about codes. Read and follow all
warnings below.
HAZARDOUS VOLTAGE. Can shock, burn or kill.
Disconnect power to motor before working on pump or motor.
Ground motor before connecting to power supply.
To avoid dangerous or fatal electrical shock, turn OFF power
to motor before working on electrical connections.
Supply voltage must be within ±10% of nameplate voltage.
Incorrect voltage can cause fire or damage motor and voids
warranty. If in doubt consult a licensed electrician.
Use wire size specified in this manual's Wiring Chart.
Wire motor according to diagram on motor nameplate. If
nameplate diagram differs from this manual's diagrams, follow
nameplate diagram.
1.
Provide a correctly fused disconnect switch for protection
while working on motor. Consult local or national electrical
codes for switch requirements*.
2.
Disconnect power before servicing motor or pump. If the
disconnect switch is out of sight of pump, lock it open and
tag it to prevent unexpected power application.
3.
Ground the pump permanently using a wire of the same size
as specified in this manual's Wiring Chart. Make ground
connection to green grounding terminal under motor
canopy marked GRD. or
4.
Connect ground wire to a grounded lead in the service
panel or to a metal underground water pipe or well casing
at least 10 feet long. Do not connect to plastic pipe or
insulated fittings.
Do not ground to a gas supply line.
5.
Protect current carrying and grounding conductors from
cuts, grease, heat, oil, and chemicals.
(*) Dual element or Fusetron time delay fuses recommended for all motor circuits.
6
.
6.
Motor has automatic internal thermal overload protection.
If motor has stopped for unknown reasons, thermal
overload may restart it unexpectedly, which could cause
injury or property damage. Disconnect power before
servicing motor.
Ground
Screw
Voltage
Change Dial
FIGURE 8 - VOLTAGE SET TO 230 VOLT CURRENT. ROTARY SELECTOR
7.
If this procedure or the wiring diagram are confusing,
consult a licensed electrician
Refer to Figure 8 for wiring configuration.
Connect current-carrying conductors to terminals
L1 and L2. When replacing the motor, check wiring
diagram on the motor nameplate. For 3-phase motors
or motor's whose wiring diagram does not match
Figure 8, follow the diagram on the motor.
115 VOLT USAGE CONFIGURATION
115/230 volt, single phase models are configured at the factory
for 230 volt usage.
If power supply will be 115 volts:
1.
Ensure power is off.
2.
Remove motor cover.
3.
Using a screwdriver or 1/2" wrench, turn the voltage
selector dial counter-clockwise to the 115 volt setting.
4.
Replace motor cover.
Power Lead
Terminals
4695
P15007 (03-01-2023)

Publicidad

loading