PREPARATION
PREPARATION:
Verify you have all parts before beginning
the installation. Check foam insert closely for
missing parts. Remove motor from packing.
To avoid damage to finish, assemble motor
on soft padded surface or use the original
foam inset in motor box.
DO NOT LAY MOTOR HOUSING ON ITS SIDE
AS THIS COULD RESULT IN SHIFTING OF
MOTOR IN DECORATIVE ENCLOSURE.
INSTALLING THE MOUNTING BRACKET
CAUTION: To avoid possible electrical shock, be sure electricity is turned off
at the main power box before wiring. All wiring must be in accordance with
National and Local Electrical Codes and the ceiling fan must be grounded as
a precaution against possible electric shock.
Locate ceiling joist where fan is to be mounted, being sure location
1
agrees with the requirements in the minimum clearance section of this
guide. Wood joist must be sound and of adequate size to support 35
lbs. (See Page 1, Items 3 and 4).
2
If not already present, mount a UL listed outlet box marked "suitable for
fan support" following the instructions provided with the outlet box. The
outlet box must be able to support a minimum of 35 pounds.
Attach mounting bracket to outlet box using screws provided with the
3
outlet box.
Parts identification on assembled fan.
Motor Housing
Glass Shade
Blade
Outlet box
Screws