2.3 Disassembling the interior hand-set
To install the interior hand-set or access the terminal block and
configuration switches:
disconnect the RJ11 plug (77) from the wired hand-set and
set it aside in a safe place.
Loosen the cover retaining screw (78).
Li the cover from the lower section.
View inside the hand-set
Mark
Description
79
Terminal block
80
Address switch - 8 selectors
Multi-monitor (or hand-set) configuration
81
switch - 4 selectors
82
BUS line closure stop
2.4 Wiring the interior hand-set
The interior hand-set is powered directly by the installation's BUS line
via the VSP-PS01 or VSP-PS02 power supply.
Cable section
Cable
CAT5 UTP/CW1308
Telephone cable
2 wires
Section
Maximum distance
(mm²)
between the external
module and the most
distant hand-set (m)
0.50
0.22
0.28
0.50
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.
Maximum distance
between the power
supply and the most
distant hand-set (m)
250
100
150
70
EN
LB
AL
GND
BUS
BUS
S1
78
81
79
LB
AL
80
GND
82
BUS
BUS
S1
100
50
50
30