TROUBLESHOOTING
PROBLEM
The machine does
not produce water
Water leakage at
connections
Water smells bad
No water comes
out of the rejection
output
Water keeps
coming out of the
rejection outlet
The device
does not stop
when the tap is
turned off
POSSIBLE CAUSE
1. Water inlet closed
2. Saturated filter
3. Saturated membrane
4. Transformer
disconnected or faulty
1. Pipe connections are
not tightened properly
2. Filters incorrectly
tightened
3. Bad filter seals
1. Long time no change
2. The machine was not
flushed before first use
1. Water inlet closed
2. Clogged PAC filter
3. Transformer
disconnected
4. Solenoid valve clogged
1. Damaged non-return
valve
2. Inlet solenoid valve
fouled or damaged
1. Clogged membrane
2. High voltage pressure
switch damaged
27
SOLUCIONES
1. Open inlet valve
2. Replace filter
3. Replace membrane
4. Connect transformer
or notify SAT
1. Tighten the connections
2. Tighten again
3. Replace
1. Let it run abundantly
and let cold water run in
2. Let it do the flushing
1. Open inlet valve
2. Replace PAC filter
3. Connect transformer
4. Clean or replace by
SAT staff
Replace by SAT staff
1. Replace membrane
2. Replace by SAT staff