The monitor will analyze the air sample and display the CO concentration in parts-per-million (ppm). The system's
green "NORMAL" operation light will illuminate and the red "HIGH CO" light will flicker faintly approximately
every second when the CO level is below 10ppm (5ppm Canadian). If the CO concentration level exceeds the alarm
set point, the green "NORMAL" light will turn off, the red "HIGH CO" light will illuminate, the audible alarm will
sound and the remote alarm connections (if used) will energize. Once the CO concentration levels drop below the
alarm set point, all alarm indicators will deactivate and the unit will return to "NORMAL" operation.
Size
2.75"H x 6.57"L x 5.1"W
Weight
2.8 LBS. (1.27KG)
Extruded aluminum - Anodized black
Case
Voltage
115 VAC and/or 9 - 16 VDC
Shielding
Internal RFI/EMI filters
115 VAC 1 amp fast acting
Fuse
Operating
4 to 113 degrees F
Temperature
(-15.5 to 45 degrees C)
Humidity
Range
10% to 90% RH
Flow
Requirement
50 - 100 cc
3 digit LCD
Display
(CO concentration)
-5-
MONITOR OVERVIEW
MONITOR SPECIFICATIONS
Test Circuit
Sensor Type
Accuracy
Response
Detectable Range
Calibration
Alarm Setting
Warning Signals
Warranty
WIRING SCHEMATIC
Manually activated
Sealed electrochemical sensor for Carbon
Monoxide
+/- 1% full scale
90% in 10-15 seconds
0 - 200ppm CO
Manual CO zero and span adjustments
10ppm CO (5ppm Canadian)
Normal operation - Green light
High CO - Red Light
High CO - Audible Alarm
Low Battery - Amber Light
2 years from original date of purchase