16
www.aeg.com
limit, the power of the cooking zones
will be automatically reduced.
• The heat setting of the cooking zone
selected last is always prioritised. The
remaining power will be divided
between the previously activated
cooking zones in reverse order of
selection.
• The heat setting display of the
reduced zones changes between the
initially selected heat setting and the
reduced heat setting.
• Wait until the display stops flashing or
reduce the heat setting of the cooking
zone selected last. The cooking zones
will continue operating with the
reduced heat setting. Change the
heat settings of the cooking zones
manually, if necessary.
Power management with Power
limitation
When you set the Power limitation
function to 6000 W or less, the power of
the hob is divided among all cooking
zones.
Refer to the illustration for possible
combinations in which power can be
distributed among the cooking zones.
When you set the Power limitation
function to more than 6000 W, the
power of the hob is divided among the
sections indicated below.
6.7 Hob²Hood
It is an advanced automatic function
which connects the hob to a special
hood. Both the hob and the hood have
an infrared signal communicator. The
speed of the fan is defined automatically
on the basis of the mode setting and the
temperature of the hottest cookware on
the hob. You can also operate the fan
manually.
For most of the hoods, the
remote system is originally
deactivated. Activate it
before you use the function.
For more information refer to
the hood user manual.
Operating the function automatically
To operate the function automatically set
the automatic mode to H1 – H6. The hob
is originally set to H5. The hood reacts
whenever you operate the hob. The hob
recognizes the temperature of the
cookware and adjusts the speed of the
fan automatically.
Automatic modes
Auto‐
matic
light
Mode H0
Off
Mode H1
On
On
3)
Mode H2
Mode H3
On
1)
2)
Boiling
Frying
Off
Off
Off
Off
Fan
Fan
speed 1
speed 1
Off
Fan
speed 1