Removal of the casing.
The hand dryer is supplied with the casing fitted to the base without tightening (Figure 1).
Carefully remove the casing since it is connected to the base by a tab that joins the two
pieces (casing and base) at the rear (Figure 2).
Remove the casing keeping it at an angle at all times (Figure 3) until the upper tab is
completely withdrawn, taking care to:
 not damage the internal components, in particular the electronic circuit,
 not scratch or damage the LED sensor screen,
not damage the surface of the casing.
ATTENTION: WHEN THE CASING IS DISMANTLED ACTIVE PARTS OF THE DEVICE
Figure 1.
Assembly
Connection to the power grid will be preferably through the rear plug.
In order to assemble the hand dryer complete the following steps:
Make four drill holes with an 8 mm (0,31") diameter in the wall, using the provided
template (Figure 4).
Clean the dust away from the holes and insert the wall plugs.
Pass the electrical cables from the power grid through the hole with the 22 mm (0,87")
diameter which is situated above the device's terminal strip (Figure 5).
Firmly screw the base of the device to the wall (Figure 6), ensuring that the 4 silent-blocks
are correctly placed between the base and the wall.
Figure 4.
BECOME ACCESSIBLE.
Figure 2.
Figure 5.
11
Figure 3.
Figure 6.