Descargar Imprimir esta página

Perel Tools AC30 Manual Del Usuario página 5

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
Note: another way to determine the charge level of the battery is by measuring the density of the
acid using a density meter (see table below).
density = 1.285g/ml
density = 1.21g/ml)
density = 1.16g/ml)
When the battery is fully charged, immediately switch off the charger [6]. Overcharging will
destroy the battery.
Disconnect the battery from the charger, starting with the clamp on the negative pole (black)
and than proceed with the clamp on the positive pole (red).
7.
Fuses
The AC30 has 3 safety fuses installed.
Thermal fuse: this fuse cuts of the output power when the temperature of the charger is too
high. Power automatically restores when the temperature drops below an acceptable level.
Input fuse [3]: protects the charger from power anomalies on the mains input power. To
replace, disconnect the charger from the mains and disconnect the connected battery. Unscrew
the holder [3] (counter clockwise) and replace the broken fuse by a fuse with the same
specifications (F5A/250V). Tightly screw the holder back in place.
Output fuse [2]: protects the connected battery from over-current. To replace, disconnect the
charger from the mains and disconnect the connected battery. Simply unplug the fuse from the
socket and install a new one. Only use a fuse with the same specifications (30A).
8.
Maintenance
• Always remove the plug from the mains socket and disconnect batteries when servicing or
cleaning the charger.
• Never use water or any other liquids to clean the charger.
• Keep the cables clean, but avoid using cleaners based on benzene, trichloroethylene, chloride,
ammonia ... as they affect or even dissolve plastic parts.
• Check liquid level of batteries once per month and fill up when necessary.
• Dispose of batteries in accordance with local regulations.
9.
Technical specifications
rated input voltage
rated output current
boost current
exchangeable fuse
reference battery capacity
IP-code
weight
dimensions
Use this device with original accessories only. Velleman nv cannot be held responsible in
the event of damage or injury resulted from (incorrect) use of this device. For more info
concerning this product and the latest version of this user manual, please visit our website
www.perel.eu. The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman nv. All worldwide rights
reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.
29/06/2010
AC30
battery fully charged
battery half charged
battery depleted
230V
~ 50Hz
AC
16A
20A
30A
min. 92Ah ~ max. 250Ah
IP20
11.6kg
375 x 260 x 210mm
5
©Velleman nv

Publicidad

loading