Descargar Imprimir esta página

SICK WI130 Manual De Instrucciones página 37

Ocultar thumbs Ver también para WI130:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 63
8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice
12
3
4
OUT
1
LSR ON
OUT
2
â
Figure 1: Function buttons
Table 1: Status indicators and function buttons of the evaluation unit
Legend
Name
number
LSR ON
1
OUT 1
2
Secondary indicator (green) Shows thresholds, function selection and quantity.
3
Main indicator (red)
4
LED for the current channel
5
(1x Out)
UP switch
6
DOWN switch
7
Teach-in button
8
Setting/operation button
9
Mode switch
ß
Teach-in LED
à
OUT 2
á
LED for the current channel
â
(2x Out)
NOTE
WI130T-P/N340 are 1x Out output type, 3 and 8 do not light up. Channel selection of
á is redundant.
Locking the control elements
Quits all operations.
Useful for avoiding errors
In RUN mode, press the switches simultaneously for two seconds or more. Do
the same to unlock.
Locking
L O C
300
OPERATING INSTRUCTIONS
5 6
7
8
T
1
2
SET
RUN
á
à
ß
9
Function
Laser LED
Switches on when the evaluation unit is supplied with
power.
Output LED
Lights up if 1x Out is switched on.
Shows light strength, function and quantity
Is permanently on when the display shows value, setting
and function for 1x Out.
Operating mode: Displays the threshold
Configuration mode: Function selection or changing the
numerical value
Operating mode: Changes the channel.
Configuration mode: Returns to operating mode or per‐
forms scaling.
Configuration mode: Starts the teach-in.
Changes between teach-in and operating mode.
Operating mode: Changes to configuration mode.
(0.5 seconds ≥)
Configuration mode: Applies setting.
Lights up during teach-in mode
Output LED
Lights up if 2x Out is switched on.
Is permanently on when the display shows value, setting
and function for 2x Out.
Unlocking
←→
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
u L O C
300
37
en

Publicidad

loading