Eliectrictli connection
First of all, unscrew the protective cover
For 6000 tnd 7000 veraiona:
Connection of the termintli bliock on 1 ainglie-phtae 32A liine with t 32A circuit bretker.
-N + N on neutral conductor
-PH front + PH rear on Phase conductor
-PE on earth conductor
Connection of the termintli bliock on 2 ainglie-phtae 16A liinea with 2 circuit bretkera.
(The neutral connections are bridged)
-N on Neutral conductor line 1
-PH front on Phase conductor line 1
-PE on earth conductor line 1
And
-N on Neutral conductor line 2
-PH rear on Phase conductor line 2
-PE on earth conductor line 2
Connection of the termintli bliock on 1 three-phtae
-N + N on Neutral conductor
-PH front on Phase conductor 1 (ph1)
-PH rear on Phase conductor 2 (ph2)
-PE on earth conductor
NB: nothing is connected on phase 3 (ph3)
Commtnd connection
It is necessary to connect the 2 cables of the
block command respectively on 2 connectors
SUBD-9.
So to lock the connections, it is imperative to
screw 2 binding screws of every connector.
Also, it is
imperative to connect the
ground wire of the block commands to the
Ground.