• The device must always be unplugged:
- before the device is moved to another place
- before the device is opened or when it is refilled with water
- in the case of malfunction
- before any cleaning
- after each use.
• Never use an extension cable that has been damaged.
• Never carry or pull the device by the power cable.
• Penetrating the housing with any kind of object is strictly prohibited.
• If the supply cord is damaged, it must be replaced by the manufacturer, an authorised representative
or a qualified person in order to avoid a hazard.
• Do not pull the power cable over sharp edges or allow it to become jammed.
• Never remove the plug from the socket by pulling at the power cable and never remove it with wet
hands.
• Do not use this humidifier in close proximity to a bath tub, shower or swimming pool (always ensure
a minimum distance of 3m). Always place the device in a position where it cannot be reached by
anyone in the bath tub.
• Do not set up the device near a source of heat. Do not subject the power cable to direct heat (such
as heat from hot oven hobs, naked flames, hot irons or heating furnaces). Keep the power cable away
from oil.
• Do not position the device directly next to walls, curtains or furniture.
• Ensure that the device is stable during operation and that no-one can trip over the power cable.
• The device is not splash-proof.
• Do not store or use the device outdoors.
• Store the device in a dry place, out of the reach of children (in its box).
• Always unplug the device when it is to be refilled with water or cleaned.
• Do not add anything to the water (fragrances, essential oils or water fresheners).
• If the power cord is damaged, it must be replaced by the manufacturer or a repair shop authorized
by the manufacturer or by similarly qualified persons in order to avoid a hazard.
• Prior to any maintenance, cleaning and after each use, switch off the appliance and unplug the mains
cable from the socket.
• Do not place the device directly on the floor. Use a water-proof underlay!
FIRST USE / OPERATION
1.
Please note: Never transport the device when it is filled with water and when upper part (2) is
attached. Otherwise water may splash into the upper part and stop the electronics from work-
ing correctly.
2.
For this reason, base (4) of the STYLIES Orion humidifier should initially be filled with water
and placed in a suitable location separately. Alternatively, the device can initially be positioned
and then filled through water filling opening (9). Insert filter cassettes (10) into the «drawers».
3.
When this base is in the desired position, place upper housing (2) back on the base. Plug power
cable (1) into the household power socket. Check that the housing is fastened securely, as a
safety contact prevents operation if the device is open.
4.
Switch on the STYLIES Orion using on / off switch (6). The desired power setting can be se-
lected using power setting button 1 or 2 (7).
5.
The desired air humidity can be selected using hygrostat button (8), from 1 LED (low humidity)
to 5 LEDs (high humidity). For example, if only 1 LED is lit, the device switches itself off at a
8
relative humidity of approx. 35%, and only starts operating again when the humidity falls below
the 35% mark. We recommend a medium setting (in the comfort zone) for an optimal air hu-
midity of around 40–60%.
Caution: the device will not switch on if the hygrostat has been set too low.
6.
As required, 1–2 drops of fragrance can be added to fragrance tray (5). This enables the
fragrance to be distributed around the room in an optimal way. Fragrances must not be added
directly to the water in the water tank.
7.
The device has a dimmer function. If the power setting button (7) is depressed for 3 seconds,
the LEDs are switched off. The device continues to operate at the previously set level. The LEDs
can be switched back on by again pressing the power setting button (7) for 3 seconds.
CLEANING PROCEDURE
•
Switch off the device and unplug the power cable from the socket before all maintenance work
and after each use.
•
Never submerge the device in water (this can result in short-circuiting). To clean the device,
simply wipe it with a damp cloth and then dry it thoroughly. Always ensure the power cable has
been unplugged beforehand.
•
Descale the humidifier as appropriate for the hardness of the water, but at least once a week:
First remove the upper part, and descale the base with a standard descaler and then rinse it
thoroughly. Reassemble the device completely before use.
•
Replace filter cassettes (10) every 2 to 3 months. Output is impaired if the filter paper has too
much limescale (as it then absorbs less water).
CLEAN CUBE
Before attaching the water tank, insert the Clean Cube in the base in the position indicated.
The Clean Cube with its patented technology prevents the growth of bacteria and germs. It can be
used for a maximum of one season, and must be replaced at the start of the next heating season
(i.e. when the weather becomes cold).
Despite using the Clean Cube, you should replace the water on a daily basis.
USEFUL INFORMATION:
Information how a evaporator works:
How does the evaporator work? Evaporator systems humidify the air and clean it by removing par-
ticles of dirt and pollen. These products achieve a highly effective humidifying effect in a natural way:
the in-built ventilator sucks dry air through water-saturated antibacterial filter cassettes. The air only
absorbs moisture until it has been enriched naturally. Excessive humidity is therefore not possible.
These systems work incredibly quietly and require very little electricity. We recommend evaporators
for use in bedrooms and children rooms.
Tips for water:
Clean water must always be used to ensure that the air remains hygienic to breathe. The device, and
the water tank in particular, must always be hygienically clean.
Recommendation: always use the Clean Cube, as this reduces the formation of germs in the water.
Hygrostat:
The standard-tolerance of an integrated hygrostat is + / - 10%. That means the effective relative
humidity level can deviate accordingly.
TROUBLE-SHOOTING
Water-shortage display (red) lights up even though device has been filled with water, ventilator does
not work:
Check that the upper part has been placed on the base correctly.
9