7 INPUTS AND OUTPUTS DESCRIPTION
The tables below provide a description of the functioning of all possible selections for both the inputs and the outputs on the NET_EXP
board. Also refer to the table confi guration parameters.
SELECTION
NONE
START
PED.
OPEN
CLOSE
OPEN_PM
CLOSE_PM
ELOCK_IN
PHOTO 1
PHOTO 2
SAFETY 1
STOP (SAS INPUT)
FCA1
FCA2
FCC1
FCC2
SAFETY 2
OPEN_INT
OPEN_EXT
AUX_IN
SAFETY INHIBITION
EN-4
Not used.
N.O. input start. In case of action, this results in the opening or closing. It may function in "inversion"
(P049=0) or "step-by-step" (P049=1) modality.
N.O. pedestrian start. In case of action, this results in the partial opening of the gate. The adjustment of the
pedestrian pace can be set with P043.
N.O. input open. In case of action, this results in the partial opening of the gate.
N.O. input close. In case of action, this results in the closing of the gate.
Dead man N.O. input open The gate opens for the amount of time in which the button is pressed.
Dead man N.O. input close The gate closes for the amount of time in which the button is pressed.
Electric lock activation N.O. input. In case of action, this leads to the activation of the "LOCK" output of the
board, see P062.
Photoelectric cell 1 N.C. input. See P050 to select the operation mode. If this is not used, bridge out the
connection.
Photoelectric cell 2 N.C. input. See P051 to select the operation mode. If this is not used, bridge out the
connection.
Sensitive edge 1 N.C. input. See P067 to select the operation mode. If this is not used, bridge out the
connection.
N.C. contact. (SAS INPUT): If connected to WARN_FIX/SAS OUTPUT of a second control unit, causes the "bank
door" to operate (disabling the opening of the second door until the fi rst is not fully closed).
Stop N.C. input. In case of action, this stops the movement during any manoeuvre. If this is not used, bridge
out the connection.
Motor 1 opening end stop N.C. input If not used, disable the input with the corresponding parameter.
Motor 2 opening end stop N.C. input If not used, disable the input with the corresponding parameter.
Motor 1 closing end stop N.C. input If not used, disable the input with the corresponding parameter.
Motor 2 closing end stop N.C. input If not used, disable the input with the corresponding parameter.
Sensitive edge 2 N.C. input. See P068 to select the operation mode. If this is not used, bridge out the
connection.
Starts the operation and enables the green light ignition (arrival at open gate) only for the internal traffi c
light. Meanwhile, if the OPEN_EXT command is given, this books the next operation and the green light of the
external traffi c light turns on at the end of the Automatic Closing Time (ACT).
Starts the operation and enables the green light ignition (arrival at open gate) only for the external traffi c
light. Meanwhile, if the OPEN_INT command is given, this books the next operation and the green light of the
internal traffi c light turns on at the end of the Automatic Closing Time (ACT).
Input for the control of the AUX_OUT output.
N.C. input SAFETY inhibition. When open, it causes the by-pass of the SAFETY inputs, which are ignored even
if activated.
INPUTS
DESCRIPTION