Digital Laser Measure
Measuring range
Measuring accuracy
- favorable condition
- unfavorable condition
Measuring time:
Lowest indication unit
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Divergence laser beam
Batteries
Weight
Dimensions
Measuring Units
A) When measuring from the back edge of the measuring tool, this applies for
high reflectivity of the target (e.g. a wall painted white), weak background
lighting and a 68°F (20 °C) operating temperature; a distance-dependent
deviation of ±0.05 mm/m must additionally be factored in.
B) When measuring from the back edge of the measuring tool, this applies for
high reflectivity of the target (e.g. a wall painted white), strong background
lighting, 68°F (20 °C) temperature and large altitudes. In addition, a deviation
of ±0.15 mm/m must be taken into account, depending on the distance.
160992A6EZ GLM100-23 202210.indd 11
Technical Data
+14° F to 113° F (-10° C to +45° C)
-4° F to 158° F (-20° C to +70° C)
4 x 1.4 x 0.9 in (100 x 36 x 23 mm)
ft decimal, inch decimal, ft-inch fractional,
-11-
GLM100-23
6 in - 100 ft (0.15 – 30 m
±1/16 in (±1.5 mm)
±5/32 in (±3.0 mm)
0.1 sec – 4.15 sec
1/32 in (0.8 mm)
635 nm, <1mW
<1.5 mrad (full angle)
2 x 1.5V LR03 (AAA)
2 x 1.2 V HR03 (AAA)
0.19 lb (0.09 kg)
inch fractional, m, cm, mm
)
A
A
B
90 %
2
10/4/22 10:19 AM