9.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the time of the supply apply.
Damage caused by:
• Improper use of the device;
• Failure to observe the requirements described in this document;
• Failure to observe the regulations pertaining to installation;
• Tampering, modification and use of non-original spare parts;
is not covered by the rights of the warranty or compensation for damage.
The warranty also excludes maintenance work, the assembly of devices of other manufacturers, making changes to the device
and natural wear.
10.0 - RATING PLATE DATA
The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
= device name/model
• Wall installation = Installation position
• IP....
= Protection rating
• 230V....
= Power supply voltage, frequency (if Vac), followed by the electrical absorption
• TS
= Temperature range within which product operation is guaranteed
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U2312
= Lot issued in year 2023 in the 12th week
• 7634
= progressive job order number for the indicated year
• 00001
= progressive number referring to the quantity of the lot
•
= Disposal in accordance with WEEE directive 2012/19/EU
11.0 - LED INDICATOR
LED
Status
Fixed
Slow flashing (0.5 Hz)
GREEN
Fast flashing (2.Hz)
Flashing
Flashing
BLUE
Flashing
RED
Fixed
M90W
Description
Power supply ON - Operation
Warm-up (about 15s)
Maintenance Required
Eprom Fail: setting data storage
problem
Sensor Fault: Accelerometer
damaged
Tilt Detected: The device is
positioned at an angle between 5°
and 10° with respect to the vertical
The system has gone into alarm
12
Mod.: M90W
Wall installation
IP65 - 230 V/50-60 Hz - 3VA
year: 2023
Lot:U2312
Action
--
--
Contact Customer Support
Press the reset button and restart the
device. If the fault persists, the device
must be replaced.
Press the reset button and restart the
device. If the fault persists, the device
must be replaced.
Check the installation position of the
device (Para. ..) Press the reset button and
restart the device. If the fault persists, the
device must be replaced.
Check the conditions of the system and the
status of the connected devices. Restore
normal safety conditions, press the reset
button and restart the device.
Madas Technical Manual - 9|9.3 - REV. 1 of 6
TS: -20+60 °C
7634/00001
Apr 2023
th