SYMPTOM
Engine will not start.
Generator has no output.
24
Troubleshooting
PROBLEM
Engine switch is off.
Fuel Tank empty.
Fuel Valve is off.
Inadequate engine oil.
No spark at spark plug.
Circuit breakers tripped.
Inadequate cord sets or
extension cords.
SOLUTION
Turn engine switch to the ON position.
Fill tank per instructions in this manual.
Turn Fuel Valve on.
Check oil level. This engine is
equipped with a low oil sensor. The
engine cannot be started unless the oil
level is above the prescribed lower
limit.
Remove the spark plug cap. Clean any
dirt from around the plug base, then
remove the spark plug. Install the
spark plug in the plug cap. Turn the
engine switch on.
Grounding the electrode to any engine
ground, pull the recoil starter to see if
sparks jump across the gap. If there is
no spark, replace the plug.
Reinstall the plug and start engine
according to instructions in this
manual.
Consult Mi-T-M Customer Service.
Reset circuit breakers.
Check cord sets or extension cords
capabilities in section Controls;
Cable Size in this manual.
Consult Mi-T-M Customer Service.
Operator's Manual