replace the container cap and agitate the con-
tainer to ensure thorough mixing of the petrol
and oil.
FILING THE FUEL TANK
Use a suitable funnel to transfer the fuel mix
from the container to the generator fuel tank,
taking care not to spill any fuel or over fill the
fuel tank.
The fuel tank should not
be filled above the top of
the fuel filter as shown in
Fig.3
STARTING THE GENERATOR ENGINE
Before starting the engine make sure that all
the electrical loads are disconnected from the
generator AC outlet socket.
Gently agitate the fuel
mix by gently rocking the
generator backwards and
forwards a few times. This
will ensure that the two-
stroke oil has not settled
out from the petrol.
Turn the fuel cock lever
to the ON position (See
Fig.4). Set the choke lever
to the ON position (see
Fig.5).
Turn the engine ON/OFF
switch to the ON position
(See Fig.6).
Hold down the generator
firmly with one hand on
the carrying handle. With
the other hand grip the
recoil starter cord handle
and pull slowly until re-
sistance is felt indicating
that the recoil starter is
engaged.
When
resis-
tance is felt pull the cord
sharply (See Fig.7).
Continue this procedure
until the engine starts.
When the engine has
been successfully started
and is running smoothly
return the choke lever
to the OFF position (See
Fig.8).
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
E N G L I S H •
STOPPING THE GENERA-
TOR ENGINE
• Before stopping the
engine, switch off all the
electrical loads and turn
the
generator
ON/OFF
switch to the OFF position
(See Fig.9).
• Before stopping the engine make sure that all
the electrical loads are disconnected from the
generator AC outlet socket.
When the generator en-
gine has stopped and
before storage, turn the
fuel cock lever to the OFF
position as shown in fig-
ure 10.
CONNECTING THE ELECTRICAL LOAD
WARNING: Before connecting any electrical
load to the generator ensure that the load does
not exceed the maximum load as stated on the
rating plate.
Ensure that the mains supply lead is long enough
to reach the generator without any strain.
When the generator en-
gine has been success-
fully started and is run-
ning smoothly connect
the electrical load into
the generator AC output
socket (See Fig.11).
OVER LOAD PROTECTION
The generator is fitted
with an overload protec-
tion device located on the
control panel (Fig.12).
In the event that the load
exceeds that stated on the
rating plate, the overload
protection will operate
and disconnect the load.
If the overload protection device is tripped.
Check the electrical load and if necessary reduce
the load. The overload protection device can be
re-set by pressing in the re-set button.
DC BATTERY CHARGING FUNCTION
NOTE: This function is ap-
plicable to 12 V battery
charging only.
Disconnect
the
leads
from the battery. Loosen
the vents on the battery.
Make sure the battery
fluid level is correct.