FCC/IC
En
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS
standards. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions may cause harmful interference to radio communications.
However, there is no guarantee interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct
theinterference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
— Consult the dealer or an experienced radio/TV technician for help
Important note: To comply with the FCC RF exposure compliance requirements, no change
to the antenna or the device is permitted. Any change to the antenna or the device could result
in the device exceeding the RF exposure requirements and void user's authority to operate
the device.
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils
exempts de licence d'Industrie Canada. Son utilisation est sujette aux deux conditions
suivantes : (1) cet appareil ne doit pas occasionner de brouillage préjudiciable et (2) cet
appareil doit accepter toutes les interférences reçues, notamment les interférences qui
peuvent provoquer un fonctionnement non désiré.
NOTE DE LA FCC : Le fabricant n'est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées
de ce matériel. De telles modifications peuvent annuler le droit de l'utilisateur à utiliser cet
appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites
ont été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable
en milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence
radio et, s'il n'est pas installé et utilisé conformément aux instructions, il peut provoquer un
brouillage préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que
des interférences ne se produiront pas au sein d'une installation donnée. Si cet appareil
occasionne un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit
d'allumer et d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons
l'utilisateur à essayer de corriger ces interférences en appliquant une ou plusieurs des
mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC
concernant l'exposition aux RF, aucune modification apportée à l'antenne ou au dispositif n'est
autorisée. Toute modification apportée à l'antenne ou au dispositif pourrait faire en sorte que le
dispositif dépasse les exigences d'exposition aux RF et pourrait annuler le droit de l'utilisateur
à utiliser ce dispositif.
Es
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC
y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria
de Canadá aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las
siguientes dos condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y (2)
este dispositivo debe aceptar toda interferencia que reciba, incluso la que pudiera causar un
funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio
o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas
modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de
Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos límites están
diseñados para proveer protección razonable contra interferencias perjudiciales en una
instalación residencial. Este equipo genera, usa y puede irradiar energía de radiofrecuencias
y, si no se instala y usa según las instrucciones, puede provocar interferencia perjudicial a
las radiocomunicaciones. No obstante, no hay garantías de que no ocurrirá interferencia en
una instalación en particular. Si este equipo provoca interferencia perjudicial a la recepción
de radio o televisión, lo que puede determinarse encendiendo y apagando el equipo, se
recomienda que el usuario intente corregir la interferencia por medio de la implementación de
una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que está
conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
Responsible Party - US Contact Information | Parte responsable - Información de
contacto de los Estados Unidos | Partie responsable - Coordonnées des États-Unis
FCC ID — U2ZZW6309 | IC: 6924A-ZW6309
Jasco Products Company | Model: ZW6309A/54325
10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
All brand names shown are trademarks of their
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
respective owners.
DISTRIBUTED BY
Tous les noms de marque illustrés sont des marques
JASCO PRODUCTS COMPANY LLC,
10 E. MEMORIAL RD.,
de commerce de leurs propriétaires respectifs.
OKLAHOMA CITY, OK 73114.
Todas las marcas que aparecen aquí son marcas
registradas de sus respectivos dueños.
©JASCO 2020 | 54325 | ZW6309A | 09/01/20 v1
1.
1.
Getting to know your new Z-Wave device
• Z-Wave certified for simple pairing and integrated home automation
• Transmits notifications to connected controller when water leaks or changes
in area temperature are detected
• Dual-detection options — contacts on the sensor base or separate plug-in
detection probe for hard-to-reach locations
• Red LED indicates programming changes and status
• Alarm for audible notification of leaks
• Supports association with up to five devices
• Easy auto pairing and button-press settings
• Automatic tamper switch with alarm
• Regular temperature and battery level reports
2.
2.
A. LED – red behind cover
B. Programming button
C. Sensor port
D. Micro USB cable port
E. Battery and battery tab
F. Top cover locking tab slot
G. Alarm siren
H. Top cover
H
I. Detachable probe
J. S2 security label/
SmartStart QR code
4.
4.
Adding your sensor in a Z-Wave network
The flood/freeze sensor can be added to the Z-Wave network automatically or manually, from battery or micro USB power. For best results, add the sensor to the network near the intended location (same room or area)
to ensure best communication routes are established.
SmartStart
This sensor is SmartStart enabled. If your controller supports SmartStart inclusion, this sensor can be added into a Z-Wave network by following the instructions for your controller or hub and scanning the Z-Wave QR
Code under the battery door or on the package when instructed. No further action is required, and the sensor will be added automatically within 10 minutes of being powered up while in range of Z-Wave network.
Manual mode
Battery power/micro USB power
1. Follow the instructions for your Z-Wave certified controller to add the sensor in the Z-Wave network.
2. Once the controller is ready to add your device, remove the top cover of the sensor (see figure 7).
3. Ensure battery is installed with the correct polarity and the battery tab has been removed (see figure 8) or ensure micro USB is plugged into USB port (see figure 9).
4. Press and release the programming button (see figure 10). This starts the manual add process. The red LED flashes quickly as it searches for a network. After 25 seconds, the LED will stop flashing if the sensor is not
added to the network. Press the programming button to manually start the add process. If it times out, the LED will stop flashing. Press and release the programming button again.
5. The controller's app will indicate if it discovers the sensor. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box or the QR code label on the product
(see below).
Enter the 5-digit code.
DSK :
Z-WAVE DSK
XXXXX
-25651-22671
-26939-47599
-19612-25872
PIN: XXXXX
-47752
6. The red LED will activate for three seconds to confirm the sensor has been added in the network.
7. Secure the top cover into place.
Note: Your controller may need to be within 10ft. of the sensor to be added.
Using the controller, you have the ability to activate groups, scenes, schedules and interactive automations when the sensor detects a leak or temperature change.
Functions may vary depending on gateway or controller.
To remove the sensor from the Z-Wave network
1. Follow the instructions for your Z-Wave certified controller to remove the sensor from the Z-Wave network.
2. Once the controller is ready to remove your sensor, press and release the programming button one time on the sensor (see figure 10).
3. The red LED will blink five times to indicate it has been removed. Secure the top cover.
To return the sensor to factory defaults and remove sensor from Z-Wave network
1. Press the programming button 10 times within six seconds (interval between presses of the button cannot be longer than one second).
2. The red LED will activate for two seconds, followed by three quick flashes to confirm the sensor has been reset. Secure the top cover into place.
Note: This should only be used if your network's primary controller is missing or otherwise inoperable.
To replace battery
1. Remove the top cover (see figure 7).
2. Remove old battery and replace with new battery. When installing new battery, ensure proper polarity.
3. Secure top cover.
MANUAL • MANUEL •
MANUAL
Smart
READ IT OR WATCH IT
Flood/Freeze with
Humidity Sensor
Read instructions or watch easy-to-follow video.
Inondation/Gel avec
Scan QR code or visit https://byjasco.com/52247i
capteur d'humidité
intelligent
Inundación/
congelación con sensor
de humedad
inteligente
Purchase additional items at
EZzwave.com or visit your local retailer.
In-Wall
Plug-in
Smart Dimmers
Smart Dimmers
In-Wall Motion
Plug-in
Switch or Dimmer
Smart Switches
Enbrighten
In-Wall
Smart LED Bulb
Smart Fan Control
Direct Wire,
Portable
In-Wall
40A Outdoor
Smart Multi
Tamper-Resistant
Smart Switch
Sensor
Smart Outlet
Battery Power
F
3.
3.
D
J
G
DSK/PIN CODE
B
C
E
A
I
DO NOT RETURN THIS
PRODUCT TO THE STORE
STOP
NE RETOURNEZ PAS
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
If you have any problems or questions, contact our U.S.-based Consumer Care at
1-800-654-8483, option 1, Monday–Friday, 7AM–8PM Central Time.
For the most up-to-date product support, accessories, electronic (PDF) format
manuals and more, visit www.byjasco.com/support.
• No user-serviceable parts in this unit.
54325
Si vous avez des problèmes ou des questions, veuillez communiquer avec notre
ZW6309A
service à la clientèle aux États-Unis au 1-800-654-8483, option 1, du lundi au
vendredi, de 7 h à 20 h, heure du Centre.
Pour le soutien relatif aux produits le plus à jour, les accessoires, les manuels en
format électronique (PDF) et plus encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro Centro de atención al cliente
con sede en EE. UU. al 1-800-654-8483, opción 1 de lunes a viernes, de 7 a.m. a 8
p.m., hora del Centro.
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
• FOR INDOOR USE ONLY
• BATTERY MAY LEAK HARMFUL LIQUIDS
OR IGNITABLE MATERIALS OR EXPLODE
CAUSING INJURY AND PRODUCT DAMAGE
• REPLACE EXHAUSTED BATTERY IMMEDIATELY
• REMOVE BATTERY IF PRODUCT IS TO BE
UNUSED FOR EXTENDED PERIODS
• DO NOT USE Z-WAVE DEVICES TO CONTROL
ELECTRIC HEATERS OR ANY OTHER APPLIANCES
WHICH MAY PRESENT A HAZARDOUS CONDITION
DUE TO UNATTENDED OR UNINTENTIONAL
OR AUTOMATIC POWER ON CONTROL
AVERTISSEMENT
• UTILISATION INTÉRIEURE UNIQUEMENT
• LE PILE PEUVENT LIBÉRER DES PRODUITS NOCIFS
OU DES SUBSTANCES INFLAMMABLES ELLES
PEUVENT ÉGALEMENT EXPLOSER, CAUSANT DES
BLESSURES OU DES DÉGÂTS MATÉRIELS
• REMPLACEZ IMMÉDIATEMENT LE PILE
DÉCHARGÉES
• RETIREZ LE PILE DANS L'ÉVENTUALITÉ D'UNE
LONGUE PÉRIODE DE NON-UTILISATION
• N'UTILISEZ PAS LES DISPOSITIFS Z-WAVE POUR
COMMANDER LES RADIATEURS ÉLECTRIQUES
OU D'AUTRES APPAREILS QUI POURRAIENT
PRÉSENTER UN DANGER EN CAS DE COMMANDE
D'ACTIVATION IMPRÉVUE, INVOLONTAIRE OU
AUTOMATIQUE
In-Wall
Add-on Switches
This device supports lifeline and notification (association group 1) supporting 5 nodes.
Lifeline association supports the "device reset locally" function. Refer to the instructions
of your controller for any available details on how this can be set.
In-Wall
Cet appareil prend en charge la ligne de sécurité et la notification (groupe d'association
Smart Switches
1) pour 5 noeuds. L'association de ligne de sécurité prend en charge la fonction 'Device
Reset Locally' (appareil réinitialisé localement). Reportez-vous aux instructions de votre
contrôleur pour obtenir tous les détails disponibles sur la façon de le régler.
Este dispositivo es compatible con el grupo de asociación 1 de la red vital (Lifeline)
y notificación, compatible con 5 nodos. El controlador Z-Wave debe configurar
Hinge Pin
esta asociación automáticamente después de la inclusión La asociación de red
Smart Door Sensor
vital es compatible con la función "dispositivo se reinicia a nivel local." Consulte
las instrucciones de su controlador para obtener detalles sobre cómo realizar la
configuración.
Plug-in
Outdoor Smart
Switch
OR
USB Power
Installation
The smart flood/freeze sensor is designed for indoor use only. Place the sensor (typically in battery power mode) near the area of potential
leaks or water source – sinks, commodes, dishwashers, washing machines, hot-water tanks, etc. The sensor can be placed on the floor,
cabinet base, etc. to allow the three pins on the bottom to contact with the water leak. The contact pins are recessed so they do not contact
the surface (see figure 1). The sensor can be safely place onto a metal surface without activating the sensor. Mounting tape (included) can be
applied to the bottom of the sensor for secure placement (see figure 2).
For hard-to-reach locations, use the mounting tape to attach the sensor to the wall. Open the sensor port to insert the detachable probe (see
figure 3). Secure with the pins pointed down using smaller mounting tape (included) (see figure 4). The contact pins are slightly recessed so
they do not contact the surface (see figure 5).
For continuous power, connect an optional micro USB cable to the power port and plug into any 5V USB power supply (see figure 6). Optional USB cable and power supply available at ezzwave.com.
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects for five years
from the original date of consumer purchase. This warranty is limited to the repair or replacement of this
product only and does not extend to consequential or incidental damage to other products that may be
used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states
do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of
incidental or consequential damage, so the above limitations may not apply to you. This warranty gives
you specific rights, and you may also have other rights which vary from state to state. Please contact
our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM – 8PM, M-F, Central Time
or www.byjasco.com if the unit should prove defective within the warranty period.
GARANTIE
Jasco Products Company garantit que ce produit est exempt de tout défaut de fabrication pour
une période de cinq ans à compter de la date de l'achat original par l'acheteur. Cette garantie se
limite exclusivement à la réparation ou au remplacement de ce produit et n'est pas applicable aux
dommages indirects ou accessoires survenus sur d'autres produits utilisés avec ce produit. Cette
garantie se substitue à toute autre garantie expresse ou implicite. Certains États ne permettent pas
de restrictions quant à la durée d'une garantie implicite ou permettent l'exclusion ou la limitation des
dommages indirects et accessoires; il se peut, par conséquent, que cette garantie ne s'applique pas
dans votre cas. Cette garantie vous confère des droits juridiques précis; vous pouvez jouir d'autres
droits qui peuvent varier d'un État à l'autre. Veuillez communiquer avec notre service à la clientèle aux
États-Unis au 1-800-654-8483 (option 1) entre 7 h et 20 h, heure du Centre ou par l'intermédiaire de
notre site web www.byjasco.com si l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
Jasco Products Company garantiza que este producto está libre de defectos de fabricación durante un
periodo de cinco años a partir de la fecha original de compra por parte del consumidor. Esta garantía
se limita a la reparación o reposición de este producto y no cubre daños indirectos o incidentales a
otros productos que se pudieran utilizar con este producto. Esta garantía reemplaza cualquier otra
garantía explícita o implícita. Algunos estados no permiten la aplicación de limitaciones respecto de
la duración de una garantía implícita o permiten la exclusión o limitación de la cláusula sobre daños
indirectos o incidentales, por este motivo las limitaciones arriba mencionadas pueden no aplicarse
en su caso. Esta garantía le otorga derechos específicos y es posible que tenga otros derechos que
pueden variar según el estado en el que vive. Por favor, comuníquese con nuestro Centro de atención
al cliente con sede en EE. UU. al 1-800-654-8483 (opción 1) entre 7 y 20 h, Hora del Centro, o a través
de nuestro sitio de internet www.byjasco.com.
ADVERTENCIA
Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
• SOLO PARA USO EN INTERIORES
• LA PILA PUEDEN PERDER LÍQUIDOS
PERJUDICIALES O MATERIALES INFLAMABLES,
O BIEN EXPLOTAR Y CAUSAR LESIONES
CORPORALES Y DAÑOS EN LOS PRODUCTOS
SPECIFICATIONS
• REEMPLACE LA PILA AGOTADAS DE INMEDIATO
Power: 1 CR123A battery (included), micro USB power 5V/500mA (not included)
• EXTRAIGA LA PILA SI NO UTILIZA EL PRODUCTO
Signal (frequency): 908.4/916MHz
DURANTE PERÍODOS EXTENDIDOS
Z-Wave range: Up to 150ft. line of sight between the wireless controller and the closest
• NO USAR LOS DISPOSITIVOS Z-WAVE PARA
Z-Wave receiver module
CONTROLAR CALENTADORES ELÉCTRICOS U
Operating temperature range: 32–104° F (0–40° C)
OTROS APARATOS ELECTRODOMÉSTICOS QUE
PUDIERAN IMPLICAR UN PELIGRO DEBIDO A UN
Temp: -20 to 50°C +/-1.5°C
ENCENDIDO SIN SUPERVISIÓN, ACCIDENTAL O
Humidity: RH20%-90%
AUTOMÁTICO
For indoor use only
Specifications subject to change without notice due to continuing product improvement
NOT FOR USE WITH MEDICAL OR
LIFE-SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER BE
USED TO SUPPLY POWER TO OR CONTROL THE
SPÉCIFICATIONS
ON/OFF STATUS OF MEDICAL OR LIFE-SUPPORT
Alimentation : 1 pile CR123A (incluses), d'alimentation par connexion micro USB 5V/500mA
EQUIPMENT.
(non inclus)
Signal (fréquence) : 908.4/916MHz
NE PAS UTILISER AVEC UN ÉQUIPEMENT
Portée Z-Wave : Distance à vue entre la télécommande et le module de réception Z-Wave le
MÉDICAL OU DE SURVIE
plus proche allant jusqu'à 150 pi (45.7m)
LES DISPOSITIFS COMPATIBLES AVEC LA
Plage de températures de fonctionnement : De 32 à 104° F (de 0 à 40° C)
TECHNOLOGIE Z-WAVE NE DEVRAIENT JAMAIS
Temp: -20 to 50°C +/-1.5°C
ÊTRE UTILISÉS POUR ALIMENTER OU
Humidity: RH20%-90%
COMMANDER LA MISE EN MARCHE OU L'ARRÊT
DE L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
Utilisation intérieure uniquement
En raison d'améliorations continues du produit, les spécifications peuvent faire l'objet de
SE PROHÍBE SU EMPLEO EN EQUIPO
changements sans préavis
MÉDICO O EQUIPO PARA EL
MANTENIMIENTO DE LAS FUNCIONES
VITALES
ESPECIFICACIONES:
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN
Alimentación: 1 pila CR123A (incluidas), alimentación por micro USB 5V/500mA (no incluido)
USAR PARA SUMINISTRAR ENERGÍA
Señal (frecuencia): 908.4/916MHz
ELÉCTRICA AL EQUIPO MÉDICO O AL EQUIPO
PARA EL MANTENIMIENTO DE FUNCIONES
Alcance de Z-Wave: Hasta 150 pies (45.7m) en línea recta entre el controlador inalámbrico y
VITALES, NI PARA CONTROLAR EL ESTADO DE
el módulo receptor Z-Wave más cercano
ENCENDIDO O APAGADO DE DICHOS EQUIPOS.
Rango de temperatura de funcionamiento: 32-104° F (0-40° C)
Temp: -20 to 50°C +/-1.5°C
Humidity: RH20%-90%
Para uso en interiores exclusivamente
Las especificaciones están sujetas a cambios sin previo aviso por las constantes mejoras a
las que se someten los productos
Accessories • Accessoires • Accesorios
35702
USB Power Adapter
To purchase compatible accessories, visit www.byjasco.com/USB
Pour acheter des accessoires compatibles, visitez www.byjasco.com/USB
Para comprar accesorios compatibles, visite www.byjasco.com/USB
NOTE: The smart flood/freeze sensor has two power options –
battery (included) or USB (adapter and cable sold separately).
When powered by batteries, the signal repeater function is
disabled to conserve battery life. When powered by USB, the
signal repeater function is active and extends your Z-Wave
network.
NOTE: The signal repeater function is determined when product
is added to the network. If the power option is changed, the
sensor must be removed, manually reset and added to the
network under the new power option. If manual reset is not
performed, the signal repeater function will not be updated. See
section 4 for manual reset method.
36601
9ft. Micro USB Cable
Z-WAVE
INTEROPERABILITY
This product can be included
and operated in any Z-Wave
network with other Z-Wave
certified devices from
other manufacturers and
applications. All non-battery
operated nodes within the
network will act as repeaters
regardless of vendor to
increase reliability of the
network.