TROUBLESHOOTING GUIDE: DESOLDERING TOOL DOES Not REMOVE SOLDER
1.
Check if the tip is heating up by applying solder to the tip. If it does not heat, follow
the steps under "Tip Will Not Heat" earlier in this manual.
2.
Turn the power supply off.
3.
Open the handle.
4.
Replace the Chamber filter if it appears dirty and full of flux.
5.
Replace the Chamber liner if it is full.
6.
Lay the edge of your hand over the top of the collection chamber to provide a seal.
Press the trigger of the tool and verify that you feel a strong suction against your
hand.
7.
If the suction is not strong, proceed to step 12. If the suction is strong and you
replaced wither the chamber filter or liner, close the tool, insert a cartridge, turn the
system on and press the trigger while melting some solder with the tip.
8.
If the solder is not sucked into the tool, clean the tip with a thin wire or Tip Cleaner.
9.
If this does not help, turn the system off, remove the cartridge, and visually inspect
the cartridge seal and chamber seal for leaks (tears, nicks, debris). Close the tool,
remove the cartridge, and place your thumb over the front opening of the tool while
pressing the trigger.
10. If you do not feel a strong suction, try replacing the chamber seal.
11. If you still do not feel a strong suction, adjust the set screw under the front lip of the
top slide latch.
12. If the suction is weak, check the air pressure (80 psi is ideal).
13. If there is still no vacuum generated by the unit, check all the air lines to the handle
for cuts, kinks or obstructions.
14. Clean the Venturi. Squirt flux cleaner in the passage (or on a fresh Venturi), the pull
the trigger for a few seconds (with the handle open).
15. If this does not work, replace the Venturi cartridge as described in "Replacing the
Venturi".
If the above steps do not result in proper performance, call your Metcal representative or
contact us through our website www.metcal.com.
Warranty
Metcal
warrants the CV-H5-DS against any defects in materials or workmanship for one (1)
year from the date of purchase by the original owner. This Warranty excludes normal
maintenance and shall not apply to any opened, misused, abused, altered or damaged items.
If the product should become defective within the warranty period, Metcal will repair or replace
it free of charge at its sole option. The repaired or replacement item will be shipped, freight
prepaid, to the original purchaser. The warranty period will start from the date of purchase. If
the date of purchase cannot be substantiated the date of manufacture will be used as the start
of the warranty period.
For contact details for Warranty and Support look for your local office details at:
www.metcal.com
6

Publicidad

loading

Productos relacionados para Metcal CV-H5-DS