2-2. Major Component Specifications
2-2-1. Outdoor Unit
CU-5E34NBE
Outdoor Unit
P.C.Board
Part No.
Controls
Circuit Fuse
Compressor
Type
Compressor Model / Nominal Output
Compressor Oil ... Amount
Coil Resistance (Ambient Temp. 25 °C)
Safety Device
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Operation cut-off control in abnormal ambient Temp.
Overload Relay
Run Capacitor
Crankcase Heater
Fan
Type
Q'ty ... Dia.
Fan Motor
Type
Model ... Q'ty
No. of Poles
Rough Measure RPM (Cool:Hi / Heat:Hi)
Nominal Output
Coil Resistance
(Ambient Temp. 20 °C)
Safety Device
Type
Over- Current Protection
Over- Heat Protection
Run Capacitor
Heat Exchanger Coil
Coil
Rows
Fin Pitch
Face Area
External Finish
Control P.C.B
CB-CMRV3656EH
Microprocessor
400V 3.15A
CC
Ohm
Model
Operation Temp.
Micro F
VAC
mm
W
Ohm
Micro F
VAC
mm
m
2
7
Noise Filter P.C.B
POW-CMRV3656EH-B1
-
250V 25A
DC Twin Rotary (Hermetic)
C-9RVN273H0H / 2,700W
FV68S ... 1,400
T - R : 0.169
T - S : 0.169
R - S : 0.169
Yes
Yes
Yes
CS-7L
Open : 115 °C, Close : 100 °C
-
-
230V 25W
Propeller
1 ... D490
DC Motor
SIC-71FW-D881-2 ... 1
8
750 / 700
81
-
Internal Controller
Yes
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.2
0.792
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
H.I.C.Board
POW-CMRV3656EH-C1
-
-