closed area, even if doors or windows are open.
• Engines operation produces carbon monox-
ide, an odorless, colorless, poison gas.
• Breathing carbon monoxide can cause nau-
sea, fainting or death.

APPLYING LOAD

This unit has been pretested and adjusted to
handle its full capacity. When starting the gen-
erator, disconnect all loads. Apply load only
after the generator is running.
Voltage is regulated via the engine speed ad-
justed al the factory for correct output. Read-
justing will void warranty.
CAUTION: When applying a load, do not
exceed the maximum wattage rating of the
generator when using one or more receptacles.
Also, do not exceed the amperage rating of
any receptacle.
SHUTTING THE GENERATOR OFF
Remove entire electrical load.
Let the engine run for a few minutes with no
load.
Move the engine switch to the "OFF" position.
(turn the key switch to "OFF" on the electrical
start models).
Do not leave the generator until it has been
completely stopped.
Close the fuel shut off valve if the engine is to
be put in storage or transported.
If cover is used, do not install it untill the gen-
erator is cool.
INITIAL START PROCEDURE
CAUTION: Do not apply a heavy electrical
load during start period (the first two to three
hours of operation).
Controlled initial start helps insurance of
proper engine and generator operation. Fol-
low engine start procedure outlined in engine
manual.
QUICK STARTING TIPS FOR UNITS THAT
HAVE BEEN SITTING FOR A WHILE
If your unit has not been used for a long period
of time and it is hard to start it, try to do some
of these easy steps before calling the custom-
ers hotline.
• Check the oil level.
• Replace the old fuel.
• Change the spark plug.
16
• Check the fuel lines. Make sure the fuel valve
is open.
• Check all generator parts for integrity.
• Clean the carburetor. (See engine manual for
service centers)

MAINTENANCE

ATTENTION: Disconnect all plugs from the
panel, and the cable of the spark plug if the
motor is of electrical starting, before any in-
spection for maintenance.
• Before each use, review the general condi-
tions for the generator, review that all the
pieces are complete, review if there are dam-
aged cables or some other condition that can
affect that the generator operates on safe
way. If a strange noise is listened to or some
abnormal vibration, turn off the generator im-
mediately. Be sure to fix the problem before
giving the generator more use. Do not use the
equipment damaged. Periodically inspect all
the screws and bolts to check they are in place
and tight.
• Keep this equipment in a clean and dry place.
For the best maintenance of the engine and
any other problem, read the engine owner's
manual.
• After the engine has become cool, remove
the excessive gasoline and store it in a contain-
er, safe and approved for that purpose.
•After the first 20 hours of use of the genera-
tor drain and replace the oil of the engine,
after that the oil must be changed every 100
working hours.
• HEAT SHIELD: Inspect to ensure that all heat
shields and heat deflectors are intact and in
place. Removing of these parts could cause se-
rious damage to the unit.
• ENGINE: Carburetor icing during the winter
months, rare atmospheric conditions could
cause an icing condition in the carburetor. If
it happens, the engine may run rough, loose
power, and may stall. Call Product Service for
more information.
NOTE: Refer to the engine manufacturer's
manual for service and maintenance of the
engine.
SERVICE AND STORAGE