ELECTRIC START
This generator model is provided with both electric start and
recoil start capabilities. Avoid prolonged cranking, as it can
damage the engine.
The battery provided is a nominal 12 volt sealed recharge-
able lead-acid battery and can be operated in any position
without leakage. It complies with non-spillable battery
regulations. Its convenient size offers a 30% reduction over
conventional batteries.
NOTE: Brand new generators are shipped with the battery
connections disconnected. The positive and negative ter-
minals must be connected to the battery before the Electric
Start feature will work.
For initial battery connection, see Connecting/Disconnect-
ing Battery.
STARTING THE ENGINE
See Figures 12 - 14.
NOTICE:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
 Unplug all loads from the generator.
 Turn the fuel valve to the ON position.
 Pull the choke out to the START position.
NOTE: If engine is warm or the temperature is above
50˚F, push the choke in to the RUN position.
 Start the engine.
Put the engine switch in the ON position.
1
Slide down and hold the lock button while pushing
2
the engine switch to the START position.
OPERATION
NOTE: The battery may require charging before the
generator can be started using only the engine switch.
Once the generator is started, the battery will charge as
the unit runs. To start the engine using the recoil starter:
Put the engine switch in the ON position.
1
Pull the recoil starter grip until the engine runs.
2
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
 Allow the engine to run for 15–30 seconds, then move
the choke to the RUN position.
STOPPING THE ENGINE
See Figures 12 - 14.
To stop the engine under normal operating conditions:
 Remove any load from the generator and allow the engine
to stabilize.
 Turn the fuel valve to the OFF position.
 Put the engine switch in the OFF position.
To stop the engine in an emergency situation:
 Put the engine switch in the OFF position.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.