Mounting this Unit
Measures to prevent the unit from toppling or dropping should be taken for safety reasons and accident
prevention during emergencies including earthquakes.
When mounting this unit on a pedestal or ceiling, remove the 4 feet on the bottom surface and use all the 4
screw holes (M5 screws) to mount.
Ceiling
Precautions for Mounting
●
Special expertise and techniques are required for mounting
this unit. Be sure to ask your dealer or a specialist to
perform mounting.
●
Depth of the screw holes (screw length) is 23 mm. Use
screws shorter than 23 mm but longer than 13 mm.
Using other screws will result in
malfunctioning or cause the unit to drop.
●
When mounting to a pedestal, ensure sufficient space
(foot height of 10 mm or higher) around the unit so that
the air inlets are not blocked.
●
Do not tilt this unit more than ±5 degrees from side to
side when using.
■
Bottom Surface
4 locations
Air inlets
●
Regardless whether the unit is still under guarantee,
JVC is not liable for any product damage caused by
mounting the unit with non-JVC ceiling fittings or when
the environment is not suitable for ceiling-mount.
●
When using the unit hanging from a ceiling, pay
attention to the surrounding temperature. When a
heater is in use, temperature around the ceiling is
higher than expected.
ENGLISH
Air inlets