CONTROL PANEL FEATURES
1
2
1. Engine Control Switch: Flip the switch to the
"ON (l)"
position and pull the recoil starter to
start the generator. Turn to the "OFF (O)"
position to turn off the generator.
2. Low Oil Indicator: The Light will be illuminated
when the engine oil level is low. Add oil.
3. 5V 2x2.4A USB:This outlet can supply 5 Volt up
to 2.4 amps.
4. Voltage Selector Switch: To select 120 Volt or
240 Volt. TURN GENERATOR OFF BEFORE
SWITCHING VOLTAGES.
5. Data Center: Push the SELECT button to display
the voltage (V), frequency (Hz) and total run
time(Hour).
6. Circuit Breaker: Protects the generator against
electrical overloads.
NOTE: Total power drawn from all outlets must not exceed the nameplate rating.
3
4
5
6
7
10
7. 120V AC, 20A Duplex, GFCI (NEMA 5-20R):May
be used to supply electrical power for operation of
120 Volt AC, 20 Amp, single phase, 60 Hz
electrical loads.
8. 120V AC, 30A Locking (NEMA L5-30R):May be
used to supply electrical power for operation of
120 Volt AC, 30 Amp, single phase, 60 Hz
electrical loads.
9. 120/240V AC, 30A Twist Lock, Single Phase,
60 Hz Outlet (NEMA L14-30R): This outlet can
supply either 120 Volt or 240 Volt output.
10. Ground Terminal: The ground terminal is used to
ground the generator.
Page 10
6
8
9
6