Descargar Imprimir esta página

Fulgor Milano SOFIA F6PGR486GS2 Instrucciones Para La Instalación página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

5 - Gas Requirement
EN
Gas Connection
• Thread the appliances pressure regulator with 1/2" male
end connection both supplied with this appliance.
• Join the pressure regulator to the entrance threads
of the Gas Manifold with gasket supplied with this
appliance. The regulator is marked with a directional
arrow indicating correct direction of gas flow. Ensure the
appliance regulator is installed with the arrow pointing
toward the gas manifold entrance.
• Connect a manual shut-off valve to the gas supply in an
accessible location for turning on or shutting off gas to
the appliance.
• Install a coupling between the regulator and the shutoff
valve to complete the connection.
• Assure all pipe joint connections are gas tight.
• Check alignment of valves after connecting the cooktop
to the gas supply to be sure the manifold pipe has not
been moved.
FOR ALTERNATIVE PIPING METHODS TO CONNECT
THE APPLIANCE TO THE GAS SUPPLY, A TRAINED
SERVICE TECHNICIAN OR GAS APPLIANCE INSTALLER
MUST MAKE THE GAS SUPPLY CONNECTION. Leak
testing of the appliance shall be conducted by the
Installer according to the Instructions given.
Unless prohibited by local codes or ordinances, a new
A.G.A. - Certified, flexible metal appliance connector may
be used to connect this appliance to its gas supply.
The connector must have an internal diameter not less than
nominal 1/2" NPT pipe, from 3-foot (* reccomended for
36'' and 48'' Full Gas ranges) to 5-foot maximum lengh,
5/8'' O.D. CSA-approved flexible metal gas supply.
* If a longer connection line is used it may result in noticeably
reduced performance if using many of the burners
simultaneously.
A 1/2" NPT x 1/2" flare union adapter is required at each
end of the flexible connector.
If a flexible connector is used assure that both the appliance
pressure regulator and manual shut-off valve are joined
solidly to other permanent hard piping (either gas supply
or the appliance manifold) so as to be physically stationary.
14
CAUTION
Do not attempt to attach the flexible connector directly to an
external pipe thread.
Connection requires flare union adapters.
MAXIMUM GAS POWER
NATURAL GAS
30"
92,000 Btu/h
36"
133,500 Btu/h
48"
151,000 Btu/h
PROPANE GAS
30"
76,000 Btu/h
36"
111,500 Btu/h
48"
127,000 Btu/h
For Massachusetts Installations:
1. Shut-off valve must be a "T" handle gas valve.
2. Flexible gas connector must not be longer than 36 inches.
3. Not approved for installation in a bedroom or a bathroom
unless unit is direct vent.

Publicidad

loading