Compression Sleeve
Nut
Adapter
9. Valve/Breaker Installation
Slide the nut and compression sleeve onto the adapter.
Apply thread sealant onto the bottom threads of the adapter.
Thread the adapter onto the bottom of the transfer valve shank.
Securely tighten the nut.
Apply thread sealant onto the short end threads of the pipe
fitting. Thread the pipe fitting onto the side of the transfer valve
shank.
Apply thread sealant onto the long end threads of the pipe fitting.
Thread the flexible hose onto the pipe fitting.
Slide the sealing washer (tapered side up) onto the transfer valve.
Kohler Co.
Sealing
Washer
Apply
Thread
Transfer
Sealant.
Valve
Apply
Thread
Sealant.
Adapter
11
Plastic
Flexible
Hose
Pipe Fitting
1009770-2-B