Basic Operation
Control Menu Options
Enable/Disable Alarm
Tap the
button repeatedly to advance to the LCD display featuring the
button to select ON or OFF alarm mode settings. The last option displayed before navigating away
from this menu option will be the selected setting.
Note: Disabling the alarm via this control menu option will silence the alarm under all conditions, including low
battery conditions.
LCD Brightness
Tap the
button repeatedly to advance to the LCD Brightness display marked "LCD". Press the
button to select Medium Backlight (default), High Backlight or Dim Backlight. The last option
displayed before navigating away from this menu option will be the selected setting.
Note: The default brightness is set at medium. Any time a button is pressed, the LCD will engage the high
brightness setting. After 2 minutes of inactivity, the backlight will revert to the selected setting until a button is
pressed.
Self-test
Tap the
button repeatedly to advance to the TEST BATT display. Press the
the test. The test will last approximately 10 seconds as the UPS switches to battery to test the
capacity with a load. Upon completion of the test, the display will indicate PAS or BAD (pass or
bad) for 20 seconds, and then return to the home screen. Connected equipment can remain on
during the test. Do not unplug your UPS to test it; this will remove safe electrical grounding.
Note: If the self-test result is BAD, it may be due to the batteries not being charged for 24 hours. Fully charge
the batteries and repeat the self-test. Please refer to the note under Step 3 on page 6.
A Replace Battery Condition will result in the Replace Battery and Warning icons flashing every
second and the audible alarm sounding repeatedly.
Scroll Control
This display option allows the user to select the option to automatically scroll each operating
condition of the UPS (such as Input Voltage, Output Voltage and Runtime) automatically.
Tap the
button repeatedly to advance to the Scroll display as shown above.
Press the
button to advance to the next available option. The last option displayed, before
navigating away from this menu option, will be the selected setting.
Note:
1. Each condition is displayed in 2 second intervals.
2. If a button is pressed while Scroll Mode is enabled, the scroll function will pause for 10 seconds to allow the
user to manually make menu selections.
20-10-127- 933184.indb 13
20-10-127- 933184.indb 13
continued
13
icon. Press the
button to initiate
10/16/2020 11:04:35 AM
10/16/2020 11:04:35 AM