BLUEHELIX TECH RRT 34 C
Calibration procedure.
•
Put the boiler (preferably) in heating mode or else in DHW mode. Press the Reset button (ref. 6 fig. 1) for 10 sec-
onds.
•
The display shows100 and the message "Co" blinking; press the "heating +" button, (ref. 4 fig. 1) to set and display 120.
•
Then press the "DHW +" button (ref. 2 fig. 1) to set 123.
•
Press the Reset button (ref. 6 fig. 1) once.
•
The display shows Ts blinking; press the "heating +" button (ref. 4 fig. 1) once.
•
The display shows Sc flashing: press the reset button once.
•
The display shows Sc alternating with 01 blinking;
•
Press the "heating +" button (ref. 4 fig. 1) to display Sc alternating with 15 blinking;
•
Press the "DHW +" button and the display shows "00";
•
Press the "DHW +" button and the display shows "01";
•
Press the "heating +" button (ref. 4 fig. 1) and the 100% calibration mode will activate, displaying the message "CA
" and "LI" alternating.
•
After calibration the display will show Sc alternating with 15 blinking.
•
Press the Reset button (ref. 6 fig. 1) for 10 seconds to exit the menu Sc.
Loading parameters with KEY
The "KEY" device allows the updating of combustion parameters for boiler type.
It is used to update the parameters or in case of circuit board replacement.
To update, disconnect the power supply, open the electrical box and insert the "KEY" device as per the instructions
provided with the kit (see also fig. 31). Close the electrical box and turn on the power to the boiler.
The display will show FH. If the system has not been drained, it is possible not to perform the "FH" phase by pressing
the button ref. 7 of fig. 1 for a few seconds. If the system has been drained, repeat the "FH" cycle.
After the cycle, the display will indicate error F67. Enter the Sc parameters (see *** 'Adjustments' on page 169 ***), scroll
to parameter SC16 by pressing the Heating "+" button.
Press the DHW "+" button to display "00".
Press the DHW "+" button once more to display "01".
Press the Heating "+" button.
The display shows "bCLd" which indicates the transfer of parameters from the KEY to the board.
If the display shows the message "ErLd" it means that the transfer of data was unsuccessful. Repeat the parameter
loading operation.
Once the transfer is complete, the display shows ECO and the delivery temperature.
Now proceed with the 100% calibration (see *** '100% calibration' on page 170 ***).
EN
1
X06
fig. 31- KEY insertion
cod. 3541N270 - Rev. 02 - 11/2017
2
X06
3
X06
171